background image

18

19

Dehumidifier

Removing the collected water

There are three ways to remove collected water

.

1. Use the bucket

• 

When the unit is off, if the bucket is full, the Full indicator light will light.

• 

When the unit is on, if the bucket is full, the compressor and the fan turn off, and the Full 

indicator light will light, the digital display shows P2.

• 

Slowly pull out the bucket. Grip the left and right handles securely, and carefully pull out straight 

so water does not spill. Do not put the bucket on the floor because the bottom of the bucket is 

uneven. Otherwise the bucket will fall and cause the water to spill.

• 

Throw away the water and replace the bucket. The bucket must be in right place and securely 

seated for the dehumidifier to operate.

• 

The machine will re-start when the bucket is restored in its correct position.

Reinstall pump hose properly

Pump hose drops

2.  Hold both sides of the 

bucket with even 

strength, and pull it 

out from the unit.

3.  Pour the water out.

1.  Pull out the 

bucket a little.

2. Continuous draining

• 

Water can be automatically emptied into a floor 

drain by attaching the unit with a water hose 

(ld

≥Φ

5/16

, not included) with a female 

threaded end (ID:M=1

, not included)

  NOTE: On some models, the female threaded 

end is included.

• 

Remove the plastic cover from the back drain 

outlet of the unit and set aside, then insert the 

drain hose through the drain outlet of the unit 

and lead the drain hose to the floor drain or a 

suitable drainage facility.

NOTE:

 

•  When you remove the bucket, do not touch any parts inside of the unit. Doing so may damage the product.

•  Be sure to push the bucket gently all the way into the unit. Banging the bucket against anything or failing to push it in 

securely may cause the unit not to operate.

•  If the pump hose drops when you remove the bucket, you must reinstall the pump hose properly to the unit before 

replace the bucket into the unit.

•  When you remove the bucket,if there is some water in the unit you must dry it.

•  When the unit is on, if the bucket is removed, the compressor and the fan turn off, then the unit will beep 8 times and 

the digital display shows Eb.

•  When the unit is off, if the bucket is removed, the unit will beep 8 times and the digital display shows Eb.

Drain hose

Female

threaded end

Remove the plastic cover 

by couterclockwise 

rotation.

3

. Pump draining (on some models)

•  Water can be automatically emptied into a floor drain or a 

suitable drainage facility by attaching the pump drain outlet 

with a pump drain hose (

Φ

od=1/4”, supplied).

•  Remove the continuous drain hose from the unit and install 

the plastic cover to the continuous drain hose outlet of the 

unit by turning it clockwise.

•  Insert the pump drain hose into the pump drain hose outlet 

for depth of 15mm at least, then lead the water hose to the 

floor drain or a suitable drainage facility.

•  Press the pump pad of the unit to activate the pump 

operation. When the bucket is full the pump starts to work.

Pump drain hose outlet

Reinstall the

plastic cover

• 

When you remove the plastic cover, if there is some water in the back drain outlet of the unit you 

must dry it. Make sure the hose is secure so there are no leaks and the end of the hose is level or 

down to let the water flow smoothly.

• 

Direct the hose toward the drain, making sure that there are no kinks that will stop the water 

flowing. Make sure the water hose is lower than the drain hose outlet of the unit.

• 

Select the desired humidity setting and fan speed on the unit for continuous draining to start.

  NOTE: When the continuous draining feature is not being used, remove the drain hose from the 

outlet, and dry the water in the continuous drain hose outlet.

Filter of the pump

Pump drain hose

NOTE:

 The pump may be very noisy when it starts to work for 3~5 minutes. It is a normal 

phenomenon.

•  Make sure the hose is secure so there are no leaks.
•  Direct the hose toward the drain, making sure that there are no kinks that will stop the water 

flowing.

•  Place the end of the hose into the drain and make sure the end of the hose is level or down to let 

the water flow smoothly. Never place it upwards.

•  Select the desired humidity setting and fan speed on the unit for pump draining to start.

NOTE:

 The pump operation on light blinks at 1Hz when the pump 

experiences an operational failure. Please turn off the unit and plug the 

power cord out. Check the following things:

•  Cleaning the filter of the pump.
•  Remove the bucket from the unit, take down the pump and clean the 

filter of the pump.

• 

Check that the pump drain hose does not link or back.

• 

Empty the water of the bucket.

• 

Reinstall the pump hose if it drops and reinstall the bucket properly. Turn on the unit. If the error 

repeats, call for service.

Summary of Contents for CD001U1-DL

Page 1: ...nderstand this manual before any assembly or use of this product Before beginning assembly of product make sure all parts are present Customer Service service hena ca 1 866 206 0888 Instruction Manual Dehumidifier Model No CD001UI DP DL ...

Page 2: ...aning turn off the power and unplug the unit 11 Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc 12 Do not drink or use the water drained from the unit 13 Do not take the water bucket out during operation 14 Do not use the unit in small spaces 15 Do not put in places where water may splash onto the unit 16 Place the unit on a level sturdy section of th...

Page 3: ...the power must be cut off to avoid damage to the machine due to lightning 7 Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over 8 Do not operate unit with a damaged cord or plug Discard unit or return to an authorized service facility ...

Page 4: ...ining flammable refrigerants See transport regulations 2 Marking of equipment using signs See local regulations 3 Disposal of equipment using flammable refrigerants See national regulations 4 Storage of equipment appliances The storage of equipment should be in accordance with the manufacturer s instructions 5 Storage of packed unsold equipment Storage package protection should be constructed such...

Page 5: ... to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation 2 Particular attention shall be paid to the following to ensure that by working on electrical components the casing is not altered in...

Page 6: ... and cylinders conform to the appropriate standards d Pump down refrigerant system if possible e If a vacuum is not possible make a manifold so that refrigerant can be removed from various parts of the system f Make sure that cylinder is situated on the scales before recovery takes place g Start the recovery machine and operate in accordance with manufacturer s instructions h Do not overfill cylin...

Page 7: ...ration Identification of parts Positioning the unit A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area such as a closet unless there is adequate circulation of air in and out of the area Do not use outdoors This dehumidifer is intended for indoor residential applications only This dehumidifier should not be used for commercial or indust...

Page 8: ...High or Normal fan speed Set the fan control to High for maximum moisture removal When the humidity has been reduced and quiet operation is preferred set the fan control to Normal TURBO Pad Press to initiate the Auto start and Auto stop feature in conjuction with the and or and buttons Timer button PUMP button on some models Press to activate the pump operation NOTE Make sure the pump drain hose i...

Page 9: ...r some models the fan motor will continue to run for 30 seconds Wait 3 minutes before resuming operation After the unit has stopped it can not be restart operation in the first 3 minutes This is to protect the unit Operation will automatically start after 3 minutes Check filter feature The system starts to count the time once the fan motor operates The check filter feature can be only activated wh...

Page 10: ...e threaded end Remove the plastic cover by couterclockwise rotation 3 Pump draining on some models Water can be automatically emptied into a floor drain or a suitable drainage facility by attaching the pump drain outlet with a pump drain hose Φod 1 4 supplied Remove the continuous drain hose from the unit and install the plastic cover to the continuous drain hose outlet of the unit by turning it cl...

Page 11: ...on when the outdoor temperature is equal to or less than 0 C 32 F otherwise water will turn to ice and cause the water hose blocked up and the unit failure Make sure to empty the bucket once a week when using the pump draining feature When the pump draining feature is not being used remove the pump drain hose from the outlet Press the pump drain hose outlet in and take the pump drain hose out from...

Page 12: ...ion No de modèle CD001UI DP DL Arrêt Veuillez lire et comprendre ce Guide avant d assembler ou d utiliser cet appareil Avant de commencer l assemblage assurez vous que toutes les pièces sont présentes Service à la clientèle service hena ca 1 866 206 0888 ...

Page 13: ... même 10 Toujours arrêter et débrancher l appareil avant de le nettoyer 11 Ne pas utiliser l appareil près de liquides ou gaz inflammables comme de l essence du benzène des solvants etc 12 Ne pas boire ou utiliser l eau provenant du déshumidificateur 13 Ne pas retirer le réservoir d eau pendant que l appareil est en marche 14 N utilisez pas l appareil dans des endroits restreints 15 Ne pas placer ...

Page 14: ...rdon sous le tapis Ne pas couvrir avec des carpettes tapis de passage ou articles semblables Éloigner le cordon des endroits passants où les gens pourraient trébucher sur le cordon 8 Ne pas faire fonctionner l appareil avec un cordon ou une fiche endommagés Jetez l appareil ou retournez le à un centre de service agréé pour examen et ou réparation 9 Pour réduire le risque de choc électrique ou d in...

Page 15: ... panneaux Voir la réglementation locale 3 Élimination de l équipement contenant des réfrigérants inflammables Voir la réglementation nationale 4 Entreposage des équipements appareils L entreposage de l équipement doit être conforme aux instructions du fabricant 5 Entreposage de l équipement emballé invendu La protection des emballages de rangement doit être fabriquée de manière à ce que des dommag...

Page 16: ...nt de retirer les couvercles scellés et autres S il est absolument nécessaire de maintenir l alimentation électrique de l équipement pendant l entretien un dispositif de détection des fuites fonctionnant en permanence doit être placé au point le plus critique pour signaler une situation potentiellement dangereuse 2 Une attention particulière doit être accordée aux points suivants afin de s assurer...

Page 17: ...st supervisé à tout moment par une personne compétente L équipement de récupération et les bouteilles sont conformes aux normes appropriées d Pompez le système de réfrigérant si possible e Si la mise à vide n est pas possible fabriquez un dispositif pour que le réfrigérant puisse être retiré des différentes parties du système f S assurer que la bouteille est située sur la balance avant de procéder...

Page 18: ...s pièces Positionnement de l appareil Le fonctionnement d un déshumidificateur dans un sous sol aura peu ou pas d effet sur le séchage d une zone de rangement fermée adjacente telle qu un placard à moins qu il y ait une circulation adéquate d air dans et hors de la zone N utilisez pas cet appareil à l extérieur Ce déshumidificateur est destiné à un usage domestique intérieur et non pour des applica...

Page 19: ...z pour choisir la vitesse HAUTE ou NORMALE Réglez la vitesse HAUTE pour maximiser la déshumidification Quand l humidité a été réduite et le fonctionnement silencieux est préférable réglez le ventilateur à la vitesse NORMALE Touche TURBO Bouton MINUTERIE Bouton POMPE certains modèles Appuyez sur ce bouton pour activer la pompe REMARQUE Assurez vous que le tuyau de vidange de la pompe est installé da...

Page 20: ...Pour certains modèles le ventilateur continuera de fonctionner pendant 3 minutes Attendez 3 minutes avant de reprendre le fonctionnement Après l arrêt de l appareil il n est pas possible de la remettre en marche dans les 3 premières minutes ceci afin de le protéger Le déshumidificateur démarre automatiquement après 3 minutes Fonction de vérification du filtre Le système commence à compter le temps...

Page 21: ...ppropriée en fixant le boyau de vidange par pompe au port de drainage à cet effet Φ diam ext 1 4 fourni Retirer le tuyau de vidange continue de l appareil et installer le couvercle en plastique sur le port de vidange continue en le serrant dans le sens horaire Posez le tuyau de vidange par pompe dans la sortie de la pompe en l insérant à au moins 15 mm de profondeur puis dirigez le tuyau d eau ver...

Page 22: ... de la pompe s égoutter sur le sol REMARQUE ne nettoyez pas le seau au lave vaisselle Après avoir été nettoyé le seau doit être fixé et bien en place pour que le déshumidificateur puisse fonctionner ATTENTION NE FAITES PAS fonctionner le déshumidificateur sans le filtre la saleté et les peluches pourraient boucher l appareil et réduire son rendement 1 Appuyez sur le port de drainage de pompe 2 Ret...