18
19
Dehumidifier
Removing the collected water
There are three ways to remove collected water
.
1. Use the bucket
•
When the unit is off, if the bucket is full, the Full indicator light will light.
•
When the unit is on, if the bucket is full, the compressor and the fan turn off, and the Full
indicator light will light, the digital display shows P2.
•
Slowly pull out the bucket. Grip the left and right handles securely, and carefully pull out straight
so water does not spill. Do not put the bucket on the floor because the bottom of the bucket is
uneven. Otherwise the bucket will fall and cause the water to spill.
•
Throw away the water and replace the bucket. The bucket must be in right place and securely
seated for the dehumidifier to operate.
•
The machine will re-start when the bucket is restored in its correct position.
Reinstall pump hose properly
Pump hose drops
2. Hold both sides of the
bucket with even
strength, and pull it
out from the unit.
3. Pour the water out.
1. Pull out the
bucket a little.
2. Continuous draining
•
Water can be automatically emptied into a floor
drain by attaching the unit with a water hose
(ld
≥Φ
5/16
”
, not included) with a female
threaded end (ID:M=1
”
, not included)
NOTE: On some models, the female threaded
end is included.
•
Remove the plastic cover from the back drain
outlet of the unit and set aside, then insert the
drain hose through the drain outlet of the unit
and lead the drain hose to the floor drain or a
suitable drainage facility.
NOTE:
• When you remove the bucket, do not touch any parts inside of the unit. Doing so may damage the product.
• Be sure to push the bucket gently all the way into the unit. Banging the bucket against anything or failing to push it in
securely may cause the unit not to operate.
• If the pump hose drops when you remove the bucket, you must reinstall the pump hose properly to the unit before
replace the bucket into the unit.
• When you remove the bucket,if there is some water in the unit you must dry it.
• When the unit is on, if the bucket is removed, the compressor and the fan turn off, then the unit will beep 8 times and
the digital display shows Eb.
• When the unit is off, if the bucket is removed, the unit will beep 8 times and the digital display shows Eb.
Drain hose
Female
threaded end
Remove the plastic cover
by couterclockwise
rotation.
3
. Pump draining (on some models)
• Water can be automatically emptied into a floor drain or a
suitable drainage facility by attaching the pump drain outlet
with a pump drain hose (
Φ
od=1/4”, supplied).
• Remove the continuous drain hose from the unit and install
the plastic cover to the continuous drain hose outlet of the
unit by turning it clockwise.
• Insert the pump drain hose into the pump drain hose outlet
for depth of 15mm at least, then lead the water hose to the
floor drain or a suitable drainage facility.
• Press the pump pad of the unit to activate the pump
operation. When the bucket is full the pump starts to work.
Pump drain hose outlet
Reinstall the
plastic cover
•
When you remove the plastic cover, if there is some water in the back drain outlet of the unit you
must dry it. Make sure the hose is secure so there are no leaks and the end of the hose is level or
down to let the water flow smoothly.
•
Direct the hose toward the drain, making sure that there are no kinks that will stop the water
flowing. Make sure the water hose is lower than the drain hose outlet of the unit.
•
Select the desired humidity setting and fan speed on the unit for continuous draining to start.
NOTE: When the continuous draining feature is not being used, remove the drain hose from the
outlet, and dry the water in the continuous drain hose outlet.
Filter of the pump
Pump drain hose
NOTE:
The pump may be very noisy when it starts to work for 3~5 minutes. It is a normal
phenomenon.
• Make sure the hose is secure so there are no leaks.
• Direct the hose toward the drain, making sure that there are no kinks that will stop the water
flowing.
• Place the end of the hose into the drain and make sure the end of the hose is level or down to let
the water flow smoothly. Never place it upwards.
• Select the desired humidity setting and fan speed on the unit for pump draining to start.
NOTE:
The pump operation on light blinks at 1Hz when the pump
experiences an operational failure. Please turn off the unit and plug the
power cord out. Check the following things:
• Cleaning the filter of the pump.
• Remove the bucket from the unit, take down the pump and clean the
filter of the pump.
•
Check that the pump drain hose does not link or back.
•
Empty the water of the bucket.
•
Reinstall the pump hose if it drops and reinstall the bucket properly. Turn on the unit. If the error
repeats, call for service.