Cool Boss Evaporative Air Cooler
26
P/N 5900275 — January 2022 — Rev. A
To shut down the Cool Boss
:
Stop the flow of water through the Media by pressing the
Cool
button twice. Verify the Pump is
indicating off on the Status Display. The
Cool
indicator should be off and the
Blast
indicator
should be on.
If using the 3/4 inch Water Source inlet, close the Valve supplying the water to the Cool Boss.
Dry the Media by leaving the Fan on in the
Blast
mode.
⚠
WARNING
Dry the Media at the end of each day to reduce the possibility of bacteria and mold
growth. Running the Fan without circulating water for 15 to 45 minutes should dry
the Media in the majority of cases. Media drying times will vary based on heat,
humidity and Fan speed.
After the Media is dry, reduce the Fan power, then turn off the Cool Boss.
Using the Timer to shut down the Cool Boss
:
Stop the flow of water through the Media by pressing the
Cool
button twice. Verify the Pump
indicates off on the Status Display. The
Cool
indicator should be off and the
Blast
indicator
should be on.
If using the 3/4 inch Water Source inlet,
close
the Valve supplying the water to the Cool Boss.
Press the
Timer
button until the desired number of hours before shut-down are displayed.
The Cooler will shut down based on the time entered. The available range is 1 to 24 hours in 1-
hour increments.
Summary of Contents for CB-20SL
Page 7: ...Cool Boss Evaporative Air Cooler 7 P N 5900275 January 2022 Rev A Specifications ...
Page 32: ...Cool Boss Evaporative Air Cooler 32 P N 5900275 January 2022 Rev A Labels ...
Page 33: ...Cool Boss Evaporative Air Cooler 33 P N 5900275 December 2021 Rev A ...
Page 34: ...Cool Boss Evaporative Air Cooler 34 P N 5900275 December 2021 Rev A Maintenance Log ...
Page 35: ...Cool Boss Evaporative Air Cooler 35 P N 5900275 December 2021 Rev A Maintenance Log ...
Page 36: ...5240 Willis Rd Theodore AL 36582 USA 2022 BendPak Inc All rights reserved bendpak com ...