5
With door several feet from closed position, disable sensing edge
TEST SENSING EDGE TERMINATION:
connection to the Transmitter.
- (D5) "Edge Activation" (AMBER) LED will light for several seconds.
When edge is first pressed;
D7
D8
D5
D6
- (D8) "Signal Acquired" (GREEN) LED will blink when edge is pressed.
Hold closed door control:
- 2 LED's under the label will be lit.
The unit will be in "Supervised Mode":
INITIAL POWER UP:
START UP / TESTING PROCEDURES
D6
GREEN
D5
AMBER
D8
GREEN
D7
RED
CHECK BATTERY
SIGNAL ACQUIRED
EDGE ACTIVATION
NORMAL MODE
LED LEGEND-RECEIVER
TRANSMITTER
(ON BOTTOM BAR)
RECEIVER
(ON OPERATOR)
Constant pressure required on door CLOSE control
- (D3) "Transmitter Awake" (GREEN) LED will blink when edge is pressed.
1)
2)
3)
1)
Electrical Edge:
- Unplug quick disconnect plug connecting
Unit should switch to "Supervised Mode":
Constant pressure required on door CLOSE control.
LED LEGEND-TRANSMITTER
TRANSMITTER SENDING
GREEN
D3
Transmitter to Sensing Edge.
GAGR
4) Receiver will switch to "Normal Mode":
- (D6) "Normal Mode" (GREEN) LED will light.
Door now requires momentary contact for CLOSE control.
- (D7) "Check Battery" (RED) LED should not be lit.
- (D6) "Normal Mode" (GREEN) LED will turn off.