background image

 

 

 

 

Important 

These pipes must remain below the water level by a 

minimum of 200mm (more is better) until elbowed into 

the vertical position. 

A minimum vertical height of 300mm above the top of 

the pool is required for both pipes. 

Control Box 

 

Mount the control box at least 1.2 meters off the ground using the 

steel bracket provided. 

Solenoid             

The solenoid must be installed in the water supply line using the 

flow direction arrow indicated on the solenoid body. 

Sensor 

  

 Refer to the diagrams 5 & 6 on the opposite page for mounting of 

the sensor 

 

 

 

The suggested method of plumbing is two 40mm class 

9PVC

 pipes plumbed 

through the pool wall and returned to the pump and filter area. 

These pipes are placed approximately 300mm below normal water level and 

finished off in the pool with push in eyeballs to match the other pool fittings. The 

pipes are usually run along the suction and return trench and elbowed up near the 

pool equipment. 

 

Installation Guide 

POOL INSTALLERS 

Sensor Pipe & Fill Plumbing 

 

Summary of Contents for Water Witch

Page 1: ...t Up Set Up Set Up Set Up Guide Guide Guide Guide utomated utomated utomated utomated p p p pool and ool and ool and ool and s s s spa water level pa water level pa water level pa water leveli i i ing...

Page 2: ...ng of water witch Page 7 Setting the sensor Page 8 Operating Mode Dip Switch Settings Page 9 Internal Block Diagram Of control Back Page Contact Information Danger This unit is powered by a 240Volt AC...

Page 3: ...ow that controls the flow of water Leveling Sensor Our patented leveling sensor designed to fit into 40mm and 50mm Class 9 pipe NOTE The sensor will not fit into 40mm Class 12 pipe When light is on st...

Page 4: ...Diagram 3 Diagrams 3 4 5 and 6 Diagram 5 Diagram 6 Diagram 4 2...

Page 5: ...sing the flow direction arrow indicated on the solenoid body Sensor Refer to the diagrams 5 6 on the opposite page for mounting of the sensor The suggested method of plumbing is two 40mm class 9PVC pi...

Page 6: ...ct your distributor as 20 30 meter cables are available Custom made longer lengths can be manufactured Sensor Solenoid Connections TX GRD RX Sol1 Sol2 Cable Colour Code Reference Diagram7 Sensor Plug...

Page 7: ...nd solenoid leads are normally 5 meters long with plugs attached for connections to the base of the control box as shown in Diagram 7 Water Witch 20 30 for the balance tank installs come with a 20 or...

Page 8: ...or left solenoid right Step 3 Turn power and water supplies on The ON light will automatically come on and begin to flash Depending on what position the sensor is in will determine if the sense light...

Page 9: ...ing up or down in the pipe Step 8 As an indicator for the position of the sensor in the pipe mark the sensor lead with a pen marker to indicate how far the sensor has been lowered into the pipe Step 9...

Page 10: ...wer lead and switch on the power The Water Witch is now set to the correct water level and mode settings TABLE ONE Dip Switch Positions relevant to pool size 8 Mode Description Capacity In LTRS SWITCH...

Page 11: ...Transformer Internal Of Control B Chip Dip switch Internal block Diagram Of Control Box Dip switch block Diagram 9...

Page 12: ...ve any questions or you have come across a problem please call us on 1300 652 076 or 03 5023 3722 or you can refer to our web site for trouble shooting and technical help www cookeindustries com au Th...