background image

 

Adjustment from Test Mode to  

OPERATING MODE

  

(DIP SWITCH SETTINGS)

 

 

 

Step 10

 

Switch the power off and unplug the power cable. 

Step 11 

Remove control box cover and set Dip Switches to 

the correct mode as indicated in the 

Table One 

below.

 

Step 12

 

Put the cover back on, plug in the power lead and 

switch on the power. 

 

The Water Witch is now set to the correct water level and 

mode settings. 

 

 

 

TABLE ONE: Dip Switch Positions relevant to pool size

 

Mode 

Description 

Capacity 

In LTRS 

SWITCH 

SWITCH 

SWITCH 

SWITCH 

TIME DELAY BEFORE 

AUTOMATICALLY 

SWITCHING WATER OFF 

Test mode 

NA 

UP 

UP 

UP 

UP 

2 Seconds 

Spa mode 

Up to 10,000 

UP 

DOWN 

UP 

UP 

13 Seconds 

Medium mode 

10,000 to 

50,000 

UP 

UP 

DOWN 

UP 

75 Seconds 

Large/Balance 
mode 

Over 50,000 

UP 

UP 

UP 

DOWN 

330 Seconds 

 

Summary of Contents for Water Witch

Page 1: ...t Up Set Up Set Up Set Up Guide Guide Guide Guide utomated utomated utomated utomated p p p pool and ool and ool and ool and s s s spa water level pa water level pa water level pa water leveli i i ing...

Page 2: ...ng of water witch Page 7 Setting the sensor Page 8 Operating Mode Dip Switch Settings Page 9 Internal Block Diagram Of control Back Page Contact Information Danger This unit is powered by a 240Volt AC...

Page 3: ...ow that controls the flow of water Leveling Sensor Our patented leveling sensor designed to fit into 40mm and 50mm Class 9 pipe NOTE The sensor will not fit into 40mm Class 12 pipe When light is on st...

Page 4: ...Diagram 3 Diagrams 3 4 5 and 6 Diagram 5 Diagram 6 Diagram 4 2...

Page 5: ...sing the flow direction arrow indicated on the solenoid body Sensor Refer to the diagrams 5 6 on the opposite page for mounting of the sensor The suggested method of plumbing is two 40mm class 9PVC pi...

Page 6: ...ct your distributor as 20 30 meter cables are available Custom made longer lengths can be manufactured Sensor Solenoid Connections TX GRD RX Sol1 Sol2 Cable Colour Code Reference Diagram7 Sensor Plug...

Page 7: ...nd solenoid leads are normally 5 meters long with plugs attached for connections to the base of the control box as shown in Diagram 7 Water Witch 20 30 for the balance tank installs come with a 20 or...

Page 8: ...or left solenoid right Step 3 Turn power and water supplies on The ON light will automatically come on and begin to flash Depending on what position the sensor is in will determine if the sense light...

Page 9: ...ing up or down in the pipe Step 8 As an indicator for the position of the sensor in the pipe mark the sensor lead with a pen marker to indicate how far the sensor has been lowered into the pipe Step 9...

Page 10: ...wer lead and switch on the power The Water Witch is now set to the correct water level and mode settings TABLE ONE Dip Switch Positions relevant to pool size 8 Mode Description Capacity In LTRS SWITCH...

Page 11: ...Transformer Internal Of Control B Chip Dip switch Internal block Diagram Of Control Box Dip switch block Diagram 9...

Page 12: ...ve any questions or you have come across a problem please call us on 1300 652 076 or 03 5023 3722 or you can refer to our web site for trouble shooting and technical help www cookeindustries com au Th...

Reviews: