background image

Manufacturer:

Kingfisher International Products Limited, 

3 Sheldon Square, London, W2 6PX, 

United Kingdom

Distributor:

B&Q plc, Chandlers Ford, Hants, 

SO53 3LE United Kingdom  www.diy.com
SFD Limited, Trade House, Mead Avenue, 

Yeovil, BA22 8RT, United Kingdom

TRAG10579 - 200000003 - Cooke and Lewis 4 Burner Gas v2c Rv2.indd   16

13/06/2017   16:00

Summary of Contents for CLGASUIT4

Page 1: ...V10617 CLGASUIT4 3663602842057 TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 1 13 06 2017 15 59 ...

Page 2: ...0 x4 G30 28 30 mbar 02 x1 03 x2 04 x1 05 x1 06 x1 08 x4 12 x4 4 x 25mm 07 x1 1 2 IMPORTANT Please read carefully the separate safety guide before use x1 TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 2 13 06 2017 15 59 ...

Page 3: ...Use 4 Use 13 Care maintenance 15 TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 3 13 06 2017 15 59 ...

Page 4: ... gases please consult the injector table later in these instructions Note any change of jets MUST be carried out by a qualified gas installer only After completing the installation ensure there is a gas tight seal around the bottom of all injectors using foam Press on the injector with your finger so that the gas outlet is closed and check for any bubbles on the connection areas of the injectors P...

Page 5: ... dissipation of heat and low power consumption Sufficient clearance is required around the appliance as shown in the diagrams above The gap between the hob and any cupboard or extractor above it must be at least 760mm TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 5 13 06 2017 15 59 ...

Page 6: ...90mm Cut an aperture in the worktop using a jigsaw as shown The worktop should be at least 30mm thick and made of a heat resistant material TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 6 13 06 2017 15 59 ...

Page 7: ...ive IMPORTANT ensure that either product is fully cured as per the manufacturer s instructions before you commence installation of the hob This hob MUST NOT be sealed or bonded into the worktop TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 7 13 06 2017 15 59 ...

Page 8: ...8 04 07 x1 07 Stretch out the supplied seal along the underside edge of the hob ensuring the ends overlap TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 8 13 06 2017 15 59 ...

Page 9: ...9 05 01 x1 01 Once the worktop edge has cured and the tape is fitted position the hob into the cutout in the worktop TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 9 13 06 2017 15 59 ...

Page 10: ...ngs complying with local regulations A connecting elbow is pre fitted to the hob This elbow terminates in an external 1 2 BSP connecting thread complying with ISO 228 1 2003 The connection made to the pre fitted elbow MUST be suitable for connecting to this thread If ANY other connection type or thread size is used a suitable adaptor MUST be fitted The qualified gas installer must ensure that the ...

Page 11: ...gas and city gas where available and the screw must be fully tightened in a clockwise direction on burners using LPG Caution The Minimum position on the burners MUST be adjusted by a qualified gas engineer only Regulation of the MINIMUM position on the burners To regulate the minimum position on the burners follow the procedure below 1 Turn on the burner and turn the knob to its MINIMUM position s...

Page 12: ...d WARNING This is a Class I appliance and MUST be earthed This appliance is supplied with a 3 core mains cable coloured as follows Brown L or Live Blue N or Neutral Green and Yellow E or Earth USE A 3AMP FUSE DOUBLE POLE SWITCHED FUSED SPUR OUTLET EUR UK Blue Brown Green Yellow N L N L N L FUSE ON This appliance requires a 3 amp Miniature Circuit Breaker To avoid the risks that are always present ...

Page 13: ...arking Rated thermal flow rate kW Rated consumption Reduced heat capacity kW Gas pressure rating mbar NATURAL GAS Methane G20 Auxiliary 0 72mm 0 95 91 lt h 0 28 20 Semi Rapid 0 97mm 1 75 167 lt h 0 45 Triple Crown 1 30mm 3 40 324 lt h 1 35 LIQUEFIED PETROLEUM GAS Butane G30 Auxiliary 0 50mm 0 90 65 g h 0 25 28 30 Semi Rapid 0 65mm 1 65 120 g h 0 40 Triple Crown 0 95mm 3 40 247 g h 1 20 LIQUEFIED P...

Page 14: ...ation Push and turn the knob around to the spark zone of the control until the gas lights Reduce the gas level to suit the cooking required If the gas fails to light first time please try again CAUTION If there is no electric current you can light the burners with a piezo electric spark gas ignitor The burners can only be lit with safety thermocouples when the knob is on MAXIMUM Do not use cooking...

Page 15: ...and maintenance section Caution Use soapy water and a cloth for cleaning Never use abrasive powders Avoid banging pots and pans down on the hob Do not leave any empty pan on the heating zone Customer helpline toll free UK 0800 324 7818 uk kingfisherservice com Eire 1800 932 230 eire kingfisherservice com TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 15 13 06 2017 16 00 ...

Page 16: ...on Square London W2 6PX United Kingdom Distributor B Q plc Chandlers Ford Hants SO53 3LE United Kingdom www diy com SFD Limited Trade House Mead Avenue Yeovil BA22 8RT United Kingdom TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 16 13 06 2017 16 00 ...

Page 17: ...TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 17 13 06 2017 16 00 ...

Page 18: ...TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 18 13 06 2017 16 00 ...

Page 19: ...TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 19 13 06 2017 16 00 ...

Page 20: ...TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 20 13 06 2017 16 00 ...

Reviews: