13
Use
Before you start
Switch on the appliance at the switched fused connection unit. The appliance is ready for use.
WARNING:
Read the instructions before using the appliance.
Functions and settings
• Flame safety device (FSD): Stops the gas supply to the gas hob when the flame goes out.
• Auto ignition.
Injector Table
Gas Category UK & IR
II2H3+ (G20 20 mbar, G30 28-30 mbar, G31 37 mbar)
Type of
gas used
Type of
burner
Injector
marking
Rated
thermal
flow rate
kW
Rated
consumption
Reduced
heat
capacity
kW
Gas pressure
rating (mbar)
NATURAL GAS
(Methane)
G20
Auxiliary
0.72mm
0.95
91 lt/h
0.28
20
Semi Rapid
0.97mm
1.75
167 lt/h
0.45
Triple Crown
1.30mm
3.40
324 lt/h
1.35
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
Auxiliary
0.50mm
0.90
65 g/h
0.25
28-30
Semi Rapid
0.65mm
1.65
120 g/h
0.40
Triple Crown
0.95mm
3.40
247 g/h
1.20
LIQUEFIED
PETROLEUM GAS
(Propane)
G31
Auxiliary
0.50mm
0.90
64 g/h
0.25
37
Semi Rapid
0.65mm
1.65
118 g/h
0.40
Triple Crown
0.95mm
3.40
243 g/h
1.20
TRAG10579 - 200000003 - Cooke and Lewis 4 Burner Gas v2c Rv2.indd 13
13/06/2017 16:00
Summary of Contents for CLGASUIT4
Page 17: ...TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 17 13 06 2017 16 00 ...
Page 18: ...TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 18 13 06 2017 16 00 ...
Page 19: ...TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 19 13 06 2017 16 00 ...
Page 20: ...TRAG10579 200000003 Cooke and Lewis 4 Burner Gas v2c Rv2 indd 20 13 06 2017 16 00 ...