Preparing for first-time use, taking out of service and disposal
CONVOVent mini / mini 2in1
47
►
Safe working
Meaning
Work performed on appliances while preparing them for first-time use and taking them out of service is
performed in special operating circumstances (e.g. with safety covers removed) or include activities
that require personnel to have relevant qualifications and appliance-specific knowledge that exceed
the requirements for operating personnel.
The measures and requirements specified in this section to ensure that the job of preparing the appli-
ance for first-time use is performed safely, also all apply similarly to the job of taking the appliance out
of service.
Requirements to be met by personnel preparing the appliance for use
The following requirements must be met by personnel preparing the appliance for first-time use:
Personnel who prepare the appliance for first-time use are employees of an approved customer
service company.
Personnel preparing the appliance for first-time use have relevant training as a service engineer.
Personnel preparing the appliance for first-time use have training specific to the appliance.
In particular, personnel preparing the appliance for first-time use must be able to assess whether
the electrical supplies have been connected to the appliance in a correct professional manner.
Damaged power cable
A risk of electric shock from damaged power cable
The appliance's power cable may become damaged during transit.
Do not install or operate the appliance if its power cable is damaged.
Live components
Risk of electric shock from live parts
When the cover is open, there is a risk of electric shock from touching live parts.
Disconnect the appliance from the power supply before removing the cover.
Missing equipotential bonding
Risk of electric shock because no equipotential bonding
Electric shock can cause burns and ventricular fibrillation.
Fasten the hood on the combi steamer so that the hood is integrated into the combi steamer's
equipotential bonding grid.
Install the electrical connection in accordance with the corresponding country-specific and local
regulations and directives.