•  The stove meets the requirements for connecting to chimneys 

dimensioned for 350°C flue gas temperature. 

•  The external diameter of the connection sleeve is 150 mm. 
•  The stove requires a draft in the chimney of at least –12 Pa. The 

draft is affected both by the length and area of the chimney, and 
by how well sealed it is. Minimum recommended chimney length 
is 3.5 m and suitable cross section area is 150-200 cm² (140-
160 mm in diameter). 

•  A flue with sharp bends and horizontal routing reduces the 

draught in the chimney. The maximum horizontal flue is 1 m, on 
the condition that the vertical flue length is at least 5 m. 

•  It must be possible to sweep the full length of the flue and the 

soot doors must be easily accessible.

•  Carefully check that the chimney is sealed and that there is no 

leakage around soot doors and flue connections.

Rear connection to a masonry chimney

The back panel must be installed before the stove is rear 
connected.

Connection to chimney

CHIMNEY

Ø approx. 180 mm

In the bag with these installation instructions 
are two wing screws for the cover.

Summary of Contents for C 850W

Page 1: ...C 850W www contura eu Installation instruction Installation instruction 2 Installasjonsanvisning 17 Monteringsvejledning 33 Guide d installation 49 GB NO DK FR ...

Page 2: ...RED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material 500 mm to side Other safety distances according to the installation instructions Risk of falling embers Approved Emissions from combustion CO 0 07 NOx 98 mg m3 OGC 51 mg m3 PM 20 mg m3 Surface temperatures Approved Cleaning options Approved Mechan...

Page 3: ...ial closer than the safe distance indicated may cause a fire Smoulder combustion can cause quick gas ignition with the risk of damage to property and personal injury A warm welcome to Contura A warm welcome to the Contura family We hope you will get a great deal of pleasure from your new stove As a new owner of a Contura stove you have secured a product with timeless design and long service life C...

Page 4: ...ove and chimney Floor plate Due to the risk of falling embers a flammable floor must be protected by a hearth plate It must extend 300 mm in front of the stove and 100 mm on each side of the stove or have a 200 mm extension on each side of the opening The hearth plate can consist of natural stone concrete metal plate or glass A painted metal or glass hearth plate is available as an accessory for t...

Page 5: ...m in diameter A flue with sharp bends and horizontal routing reduces the draught in the chimney The maximum horizontal flue is 1 m on the condition that the vertical flue length is at least 5 m It must be possible to sweep the full length of the flue and the soot doors must be easily accessible Carefully check that the chimney is sealed and that there is no leakage around soot doors and flue conne...

Page 6: ...inted non flammable walls we recommend that the same side distance as to combustible walls is used Example of an approved firewall is 120 mm solid brick with the following values Thermal conductivity λ 0 6 0 7 W m K Density 1500 1700 kg m as well as Specific heat capacity c 840 J kg K Indirect air supply through the external wall Supply of combustion air Combustion air can be supplied via a duct f...

Page 7: ...l and mark the mounting holes that you intend to use Choose a hole so that it ends up as far away from any mortar joints as possible Predrill the hole with an 8 mm masonry drill the hole must be at least 80 mm deep Clean the hole thoroughly and secure the back plate to the chimney breast with the 6 masonry screws supplied Screws that do not engage must be considered ineffective and moved to anothe...

Page 8: ...o 7 CHROM E 4 6 5 3 50 mm GB 8 ASSEMBLY Ensure that the pipe protrudes 50 mm from the back plate and seal using the sealing yarn between the wall connector and the connection pipe If further sealing material is required heat resistant sealant may be used ...

Page 9: ...7 9 8 GB 9 ASSEMBLY ...

Page 10: ...11 10 GB 10 ASSEMBLY Secure the brackets using 2 screws at the lower edge ...

Page 11: ...12 13 14 GB 11 ASSEMBLY Place the rating plate with production number and installation distance on the protective plate with the plate turned downwards ...

Page 12: ...emely important that the installation is inspected by an authorised chimney sweep before the stove is used Also read the Lighting instructions before lighting for the first time Final inspection of the installation ASSEMBLY ...

Page 13: ...Removal Handle the firebricks with care Lift the smoke baffle with one hand whilst removing the sides The side posts need not be removed when sweeping Reinstall in reverse order How to remove the firebricks REMOVAL ...

Page 14: ......

Page 15: ......

Page 16: ...E AB Box 134 SE 285 23 Markaryd Sweden www contura se Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice The current edition can be downloaded from www contura eu ...

Reviews: