• The stove meets the requirements for connecting to chimneys
dimensioned for 350°C flue gas temperature.
• The external diameter of the connection sleeve is 150 mm.
• The stove requires a draft in the chimney of at least –12 Pa. The
draft is affected both by the length and area of the chimney, and
by how well sealed it is. Minimum recommended chimney length
is 3.5 m and suitable cross section area is 150-200 cm² (140-
160 mm in diameter).
• A flue with sharp bends and horizontal routing reduces the
draught in the chimney. The maximum horizontal flue is 1 m, on
the condition that the vertical flue length is at least 5 m.
• It must be possible to sweep the full length of the flue and the
soot doors must be easily accessible.
• Carefully check that the chimney is sealed and that there is no
leakage around soot doors and flue connections.
Rear connection to a masonry chimney
The back panel must be installed before the stove is rear