PRODUCT

Product type 

Stove lit with solid biofuels 

Type designation 

Contura 850W

Manufacturing number 

See rating plate on the stove 

Intended area of use 

Heating of rooms in residential buildings 

Fuel 

Wood

MANUFACTURER

Name 

NIBE AB / Contura 

Address 

Box 134, Skulptörvägen 10 

 

SE-285 23 Markaryd, Sweden

CHECKS

According to AVCP 

System 3 

European standard 

EN 13240:2001 / A2:2004   

Test institute 

Rein-Ruhr Feuerstätten Prüfstelle, NB 1625,

 

has checked declared performance and issued test report no. RRF-40 11 2656 

PERFORMANCE DECLARATION

No. C850W-CPR-130610-SE-1

DECLARED PERFORMANCE

Essential characteristics

Performance

Harmonised technical
specification

Reaction to fire

A1 WT

Minimum distance to combustible material

500 mm to side  
Other safety distances according to 
the installation instructions

Risk of falling embers

Approved

Emissions from combustion

CO           0.07% 
NOx         98 mg/m

3

 

OGC         51 mg/m

3

 

PM           20 mg/m

3

Surface temperatures

Approved

Cleaning options

Approved

Mechanical durability

Approved

Emissions of hazardous substances

Approved

Nominal output

4 kW

Efficiency

82%

Flue gas temperature in connector at nominal 
output

320°C

EN 13240:2001 / A2:2004

The undersigned is responsible for the manufacture and conformity with the declared performance.

Niklas Gunnarsson,

 

Business area manager NIBE STOVES

 

Markaryd, 1st July 2013

CERTIFICATE

Summary of Contents for C 850W

Page 1: ...C 850W www contura eu Installation instruction Installation instruction 2 Installasjonsanvisning 17 Monteringsvejledning 33 Guide d installation 49 GB NO DK FR ...

Page 2: ...RED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material 500 mm to side Other safety distances according to the installation instructions Risk of falling embers Approved Emissions from combustion CO 0 07 NOx 98 mg m3 OGC 51 mg m3 PM 20 mg m3 Surface temperatures Approved Cleaning options Approved Mechan...

Page 3: ...ial closer than the safe distance indicated may cause a fire Smoulder combustion can cause quick gas ignition with the risk of damage to property and personal injury A warm welcome to Contura A warm welcome to the Contura family We hope you will get a great deal of pleasure from your new stove As a new owner of a Contura stove you have secured a product with timeless design and long service life C...

Page 4: ...ove and chimney Floor plate Due to the risk of falling embers a flammable floor must be protected by a hearth plate It must extend 300 mm in front of the stove and 100 mm on each side of the stove or have a 200 mm extension on each side of the opening The hearth plate can consist of natural stone concrete metal plate or glass A painted metal or glass hearth plate is available as an accessory for t...

Page 5: ...m in diameter A flue with sharp bends and horizontal routing reduces the draught in the chimney The maximum horizontal flue is 1 m on the condition that the vertical flue length is at least 5 m It must be possible to sweep the full length of the flue and the soot doors must be easily accessible Carefully check that the chimney is sealed and that there is no leakage around soot doors and flue conne...

Page 6: ...inted non flammable walls we recommend that the same side distance as to combustible walls is used Example of an approved firewall is 120 mm solid brick with the following values Thermal conductivity λ 0 6 0 7 W m K Density 1500 1700 kg m as well as Specific heat capacity c 840 J kg K Indirect air supply through the external wall Supply of combustion air Combustion air can be supplied via a duct f...

Page 7: ...l and mark the mounting holes that you intend to use Choose a hole so that it ends up as far away from any mortar joints as possible Predrill the hole with an 8 mm masonry drill the hole must be at least 80 mm deep Clean the hole thoroughly and secure the back plate to the chimney breast with the 6 masonry screws supplied Screws that do not engage must be considered ineffective and moved to anothe...

Page 8: ...o 7 CHROM E 4 6 5 3 50 mm GB 8 ASSEMBLY Ensure that the pipe protrudes 50 mm from the back plate and seal using the sealing yarn between the wall connector and the connection pipe If further sealing material is required heat resistant sealant may be used ...

Page 9: ...7 9 8 GB 9 ASSEMBLY ...

Page 10: ...11 10 GB 10 ASSEMBLY Secure the brackets using 2 screws at the lower edge ...

Page 11: ...12 13 14 GB 11 ASSEMBLY Place the rating plate with production number and installation distance on the protective plate with the plate turned downwards ...

Page 12: ...emely important that the installation is inspected by an authorised chimney sweep before the stove is used Also read the Lighting instructions before lighting for the first time Final inspection of the installation ASSEMBLY ...

Page 13: ...Removal Handle the firebricks with care Lift the smoke baffle with one hand whilst removing the sides The side posts need not be removed when sweeping Reinstall in reverse order How to remove the firebricks REMOVAL ...

Page 14: ......

Page 15: ......

Page 16: ...E AB Box 134 SE 285 23 Markaryd Sweden www contura se Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice The current edition can be downloaded from www contura eu ...

Reviews: