background image

GB

50

CERTIFICATE

PRODUCT

Product type 

Stove lit with solid biofuels 

Type designation 

Contura 850

Manufacturing number 

See rating plate on the stove 

Intended area of use 

Heating of rooms in residential buildings 

Fuel 

Wood

MANUFACTURER

Name 

NIBE AB / Contura 

Address 

Box 134, Skulptörvägen 10 

 

SE-285 23 Markaryd, Sweden

CHECKS

According to AVCP 

System 3 

European standard 

EN 13240:2001 / A2:2004   

Test institute 

Rein-Ruhr Feuerstätten Prüfstelle, NB 1625,

 

has checked declared performance and issued test report no. RRF-40 11 2656 

PERFORMANCE DECLARATION

No. C850-CPR-130610-SE-1

DECLARED PERFORMANCE

Essential characteristics

Performance

Harmonised technical
specification

Reaction to fire

A1 WT

Minimum distance to combustible material

100 mm to rear
500 mm to side  
Other safety distances according to 
the installation instructions

Risk of falling embers

Approved

Emissions from combustion

CO           0.07% 
NOx         98 mg/m

3

 

OGC         51 mg/m

3

 

PM           20 mg/m

3

Surface temperatures

Approved

Cleaning options

Approved

Mechanical durability

Approved

Emissions of hazardous substances

Approved

Nominal output

4 kW

Efficiency

82%

Flue gas temperature in connector at nominal 
output

320°C

EN 13240:2001 / A2:2004

The undersigned is responsible for the manufacture and conformity with the declared performance.

Niklas Gunnarsson,

 

Business area manager NIBE STOVES

 

Markaryd, 1st July 2013

Summary of Contents for C 850

Page 1: ...C 850 www contura eu Installation Instructions ...

Page 2: ...ECLARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material 100 mm to rear 500 mm to side Other safety distances according to the installation instructions Risk of falling embers Approved Emissions from combustion CO 0 07 NOx 98 mg m3 OGC 51 mg m3 PM 20 mg m3 Surface temperatures Approved Cleaning opti...

Page 3: ...a family We hope you will get a great deal of pleasure from your new stove As a new owner of a Contura stove you have secured a product with timeless design and long service life Contura also has combustion that is both environmentally friendly and efficient for the best heat production Read through these installation instructions carefully before installation Read how to best light your stove in ...

Page 4: ...bout how the stoves must be assembled and installed To ensure the function and safety of the stove we recommend that the installation is carried out by an authorised technician Contact one of our dealers who can recommend suitable technicians Building application These main instructions may give guidance which would contravene national building regulations Please refer to supplementary instruction...

Page 5: ...N Prior to installation If the insert needs to be put down to be moved loose components should be removed This is described at the end of these installation instructions 1 Fire bars 2 Grate disc 3 Fire bricks 4 Type plate 5 Hot air grate ...

Page 6: ...0 mm The stove requires a draft in the chimney of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is Minimum recommended chimney length is 3 5 m and suitable cross section area is 150 200 cm 140 160 mm in diameter A flue with sharp bends and horizontal routing reduces the draught in the chimney Maximum horizontal flue is 1 m on the conditio...

Page 7: ...ust be selected In hot areas the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor plastic It is important that the lead in between the pipe and the wall or floor is sealed using jointing compound A 1 m length of condensation insulated ducting for combustion air is available as an accessory Through the external wall Indirect air supply through the external wall Thr...

Page 8: ... flue also note the safety distance requirements of the flue The safety distance between an un insulated flue and a combustible part of the building should be at least 450 mm Installation distances WHEN INSTALLING TURNTABLE OPTION the fol lowing installation distances do not apply See the separate turntable installation instructions A height from floor to chimney connection upwards B height from f...

Page 9: ...EMBLY Installing C 850 Final inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used Also read the Lighting instructions before lighting for the first time ...

Page 10: ...EMOVAL How to remove the fire bricks Handle the vermiculite with care Lift the smoke baffle with one hand whilst removing the sides The side posts need not be removed when sweeping Reinstall in reverse order Removal ...

Page 11: ......

Page 12: ...ntura reserves the right to change dimensions and procedures described in these instructions at any time without special notice The current edition can be downloaded from www contura eu NIBE AB Box 134 285 23 Markaryd Sweden www contura eu ...

Reviews: