C 850
GB
56
730
500
300
200
400
100
200
300
280
100
Combustible wall
INSTALLATION DISTANCES
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate. Also applies to
separate glass hearth plates (accessory).
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
decoration must be at least 1 m.
The dimension diagrams only
show the minimum permitted
installation distances for the
stove. When connecting to a steel
flue, also note the safety distance
requirements of the flue. The
safety distance between an un-
insulated flue and a combustible
part of the building should be at
least 450 mm.
Installation distances
WHEN INSTALLING TURNTABLE (OPTION)
the fol-
lowing installation distances do not apply.
See the separate turntable installation instructions.
A = height from floor to chimney
connection upwards
B = height from floor to c/c chimney
connection rear
C = height from floor to air inlet
D = height from floor to lower edge
of hatch
Permitted area for
combustible parts
of the building
A separate glass hearth
plate (accessory) increases
the connection height to
the chimney by 6 mm.
460
915
D 335
2000
100
200
Combustible roof
360
180
A 877*
115
B 785*
C 300
45
Ø150
Air inlet Ø67
428
656
200
200
Combustible wall
430**
700
1000
230
50
200**
Fire-retardant wall of
brick or concrete
278**
506**
50**
50**
Fire-retardant wall of
brick or concrete
!