SOLO™ Access Control System

Part Code: CS-AC-3210

Introduction

The Controlsoft® SOLO™ is a complete standalone single 

door access control system for use with Controlsoft 

Proximity Cards or Fobs.  This low cost controller has a 

three digit LED display and two push buttons which are 

used to program the system.  

The SOLO is supplied with one reader head, suitable for 

indoor and outdoor use.  An optional second reader head 

can be connected to provide IN and OUT readers.

Three versions are available:

CS-AC-3210 

= Controller with Mullion reader 

CS-AC-3210-V

 = Controller with Vandal Resistant reader

CS-AC-3210-P

 = Controller with Panel Mount reader 

Technical Specifications

Power:

    12V to 24V (ac or dc).

Current:

  100mA @ 12V with 1 reader head.

Readers:

 One or two compatible reader heads: 

 

  CS-AC-3211 Mullion

 

  CS-AC-3212 Vandal Resistant or 

 

  CS-AC-3213 Panel Mount.

Inputs:

   Normally Open Door Contact / Normally Open Fire Alarm / Normally Open  

               Request to Exit (REX) button.

Outputs:

 Lock / Siren.

Display:

  Indicates the status of the controller for programming.

Buttons:

 Used to program the door controller.

Jumper:

  Configures the controller for One or Two readers.

Users:

     Up to 999

Step 1. Install the Controller

Separate the cover from the base.

Using the base as a template, mark the 3 mounting points top right, top left and 

bottom centre and any cable entry holes.  Drill and plug the holes (if required) and 

mount the base.

Install the reader according to the instructions supplied with the reader.

www.controlsoft.com

9010-0011 Issue 3

Installation Instructions 

Summary of Contents for SOLO CS-AC-3210

Page 1: ...s Power 12V to 24V ac or dc Current 100mA 12V with 1 reader head Readers One or two compatible reader heads CS AC 3211 Mullion CS AC 3212 Vandal Resistant or CS AC 3213 Panel Mount Inputs Normally Ope...

Page 2: ...oller for 1 reader head To use two reader heads remove the jumper and fit it across both pins as shown NOTE If this jumper is not in the correct position the system may experience seemingly random or...

Page 3: ...blocks 1 and 8 The Fire Alarm Panel must provide voltage free normally open contacts Step 5 Connect Outputs The SOLO has two relay outputs one for the electric door lock and the other for an alarm si...

Page 4: ...eakglass applies power to the door strike to ensure that the door is released in an emergency ALWAYS fit a MOV across the coil of the door strike to prevent Back EMF from damaging the SOLO Siren Use t...

Page 5: ...buttons and wait 30 seconds for the display to clear then try again ENROL USERS Present the Master Card to a reader for approximately 5 seconds until the controller beeps once and then three times Thi...

Page 6: ...lt up to 4 minutes 30 seconds in intervals of 30 seconds Program Timers Press and release button S1 The display will show t 1 This indicates the default Door Release Time of 1 second Press and release...

Page 7: ...0 0 1 Repeatedly press S1 until required user number shown Press and hold S2 beep Door Release Time Door Open Alarm Duration Press S1 t 1 1 second Default Press S1 t 2 2 seconds etc up to Press S1 t 9...

Page 8: ...e feel free to photocopy this page to record further users SOLO User List Controlsoft UK 44 0 1451 844896 support controlsoft com controlsoft uk support Information on all our products can be found on...