3.2.2.4
CORRECTION FACTOR menu
It is a proportional correction multiplier factor, the instrument uses in the calculation of
the estimate of strength. It is originally set to 1. It can be used to consider external factors
(for example humidity) that might influence the result and is independent from form
factors and age. The interpretation of this factor is at the discretion of the operator,
according to his experience.
The current value can be changed or reset directly to the default value (1.0).
Fig. 3-13
•
EDIT: it allows entering a coefficient
•
SET = 1 : to reset the factor to 1.