Battery Back Up Installation
Battery Back Up (optional)
The opener has provision for a Battery Back Up kit that
allows continued operation of the door in the absence of
mains power.
Installation
Disconnect power to the opener.
1.
Remove screws and swing the cover open
2.
(Fig. 40)
.
Mount battery pack and secure with item 11 and 12.
3.
Mount the SBY-3 Charger Board on the pre-mounted
4.
hex spacers and secure with three (3) M4x8 screws.
Feed the 2-wire battery harness through the grommet
5.
on the base plate and connect to the SBY-3.
Feed the charger harness from SBY-3 to the control
6.
board. Plug the 4-pin connector marked “SBY-3” onto
the control board.
Warning:
After the next step the opener may
become active (even when power is off) due to a
residual charge in the batteries.
7. Connect item 3 and 7 together
(Fig. 40)
.
8. Reconnect power.
Testing Battery Back Up
Press either the OPERATE button or transmitter
1.
to activate the opener.
Whilst the door is in motion disconnect mains
2.
power - the opener should continue to operate.
note:
Wait for the door to complete its
travel before proceeding to the next step
Press either the OPERATE button or transmitter
3.
to activate the opener.
Whilst the door is in motion re-connect power.
4.
The door should complete the cycle as normal.
Troubleshooting
If door stops or moves very slowly under battery power,
then the batteries may have little to no charge.
To remedy this connect mains power and leave the
batteries to charge. The batteries may take 24 to 48
hours to reach their maximum charge capacity.
Fig. 40
Diamond PD
Power Drive
: Instruction Manual
© Copyright 2007 B&D Doors
23
Controll-A-Door
®
P
Diamond
Instruction Manual