![Control Techniques UD53 User Manual Download Page 24](http://html.mh-extra.com/html/control-techniques/ud53/ud53_user-manual_2658680024.webp)
UD53 User Guide
Issue code: 53nu3
20
16.08
Simulated-encoder F/D output
enable
ô
0 ~ 1
ð
0
RW Bit
Use
16.08
to select the output mode of terminals 40, 41, 43, 44, as follows:
16.08
Output mode
0
AB quadrature signals
1
Frequency and direction signals
16.09
Resolver phase offset
ô
0 ~ 6143
ð
1/6143 rev.
RW Uni
S
P
16.09
indicates the value of phase offset. See
Phase offset
in Chapter 5
Setting up the UD53
for ways in which the value is entered.
The value is saved at power-down and is changed only when one of the
procedures indicated in
Phase offset
is performed.
When the operating mode of the Drive is changed,
16.09
is reset to zero.
Restoring default values does not affect the value of
16.09
.
16.10
Resolver turns ratio
select
ô
0 ~ 1
ð
0
RW Uni
Note
This parameter is available only with the following:
UD53 version 2 onward
Drive software version V03.xx.07 onward
Set
16.10
as follows to select the required resolver turns ratio:
16.10
Turns ratio
0
3:1
1
2:1