![Control Techniques UD53 User Manual Download Page 22](http://html.mh-extra.com/html/control-techniques/ud53/ud53_user-manual_2658680022.webp)
UD53 User Guide
Issue code: 53nu3
18
6.3
Parameter descriptions
16.01
Option module fitted
code
ô
0 ~ 100
ð
RO Uni
P
16.01
indicates the type of small option module that is fitted in the Drive,
as follows:
0
No small option module
1
UD50 Additional I/O
2
UD51 Second encoder interface
3
UD53 Resolver interface
4
UD52
SIN
-
COS
encoder
16.02
Resolver
RPM
ô
±
30 000
ð
RPM
RO
Bi
P
16.02
indicates the speed of rotation of the resolver.
16.03
Resolver position
ô
0 ~ 16383
ð
rev/16384
RO Uni
P
16.03
indicates the absolute position of the motor shaft (the indication
takes into account any phase offset entered in
16.09
Resolver phase offset
).
16.05
Resolver phasing test
ô
0 ~ 1
ð
0
RW Bit
Set
16.05
at
1
to initiate the resolver phasing test (on completion,
16.05
automatically returns to 0). See
Phase offset
in Chapter 5
Setting up the
UD53
.