Issue Number: 3
5
1 Introduction
NOTE
Unidrive parameters are denoted in this manual by “#MM.PP”, where
MM refers to the menu number, and PP refers to the parameter
number within that menu. Please refer to the Unidrive Advanced User
Guide for a full list of parameter definitions.
1.1 Profibus-DP
Interface
for
Unidrive
The Unidrive Profibus-DP interface is supplied as an option module,
with the Profibus-DP using a UD70 as the host. The UD70 does not
lose any functionality when the Profibus-DP interface is fitted. The
fastest data rate currently supported is 1.5 Mbits/sec.
The Unidrive supplies all power requirements for the Unidrive Profibus-
DP interface. There is no provision for a back-up +24V power supply.
1.2 Product
Conformance
Certification
The Unidrive Profibus-DP interface (with V2.05.00 firmware, V2.08.00
system file and V5.0 GSD file) was submitted to the PROFIBUS
Nutzerorganisation for conformance testing. All tests were successful,
and the PROFIBUS Nutzerorganisation awarded full Profibus
Conformance Certification. (Profibus Certificate No. Z00600)
NOTE
Unidrive Profibus-DP interfaces fitted with V2.04.00 firmware or earlier
do NOT have Product Conformance Certification.
1.3 Overview
Specification
•
Auto slave configuration of data format and data consistency
during Profibus-DP network initialisation.
•
Supported data rates (bits/sec): 1.5M, 500k, 187.5k, 93.75k, 19.2k,
9.6k
•
Three 16 bit input/output words, all can be mapped to or from
Unidrive parameters
•
CT Single Word Format non-cyclic data channel