Install TelePACE Software 

Insert TelePACE Programming Software Diskette #1 into the computer floppy diskette drive and run 
the 

setup.exe

 file included on this diskette. Follow the instructions and install the TelePACE 

Programming Software to the computer hard drive. 

 

3.5 

Configure Computer Serial Port 

 

Open the TelePACE program and select 

Communications – PC Serial Port Settings

 from the 

pull-down menu bar. 

 

Select the 

Default

 button (lower right side of dialog box) and then change the 

Port 

(upper right 

side of dialog box) to reflect the computer serial port assignment. 

 

Select 

OK

 to close the dialog box. 

com2 

Null Modem 
Cable 

Summary of Contents for SCADAPack Micro 16

Page 1: ...ro 16 Quick Start Guide CONTROL MICROSYSTEMS SCADA products for the distance 48 Steacie Drive Telephone 613 591 1943 Kanata Ontario Facsimile 613 591 1022 K2K 2A9 Technical Support 888 226 6876 Canada...

Page 2: ...eleSAFE TelePACE SmartWIRE SCADAPack TeleSAFE Micro16 and TeleBUS are registered trademarks of Control Microsystems Inc All other product names are copyright and registered trademarks or trade names o...

Page 3: ...t Mode 5 3 3 3 Connect Computer to TeleSAFE Micro 16 5 3 4 4 Install TelePACE Software 6 3 5 5 Configure Computer Serial Port 6 3 6 6 Select Controller Type 7 3 7 7 Configure Register Assignment 7 3 8...

Page 4: ...substitute for the TelePACE Ladder Logic and TeleSAFE Micro 16 Controller manuals but rather as a companion to these manuals A strong background in both programmable logic controllers PLC and personal...

Page 5: ...cified in Section 18 1J2 of the Canadian Electrical Code for installations within Canada and in accordance with the authority having jurisdiction WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MA...

Page 6: ...the I O database registers to their default values erases the Register Assignment Ladder Logic and C programs and unlocks the controller Hold down the LED POWER button Apply power to the Micro 16 cont...

Page 7: ...structions and install the TelePACE Programming Software to the computer hard drive 3 5 Configure Computer Serial Port Open the TelePACE program and select Communications PC Serial Port Settings from...

Page 8: ...les are to be used select ADD and enter the module which corresponds to the particular 5000 Series module Select a module address from the Address box and ensure that the 5000 Series module s dipswitc...

Page 9: ...16 controller with an on board DIN 5203 4 digital inputs module and an AIN 5501 analog input module addressed as 0 3 8 Configure Controller Serial Ports Select Controller Serial Ports and modify the s...

Page 10: ...t Monitor List and add the registers that are to be monitored to the Monitor Addresses list on the right side of the dialog This is accomplished by either selecting addresses from the Addresses in Use...

Page 11: ...de October 19 2007 10 To Switch to Debug to monitor the program execution select Yes The following Monitor List will appear and display the registers that were added to the Monitor List in step 11 The...

Page 12: ...United States may call our technical support department free of charge You will be connected to the nearest support center to your time zone Telephone 1 888 226 6876 1 888 2CONTROL Kanata Technical S...

Reviews: