Figure 1.

 

 Strip wire insulation

Identify your wiring application, and then see the appropriate wiring diagram 

in the “Sample Wiring Configurations” section below.

IMPORTANT!  

Not grounding this product, as described in the section 

“Warnings and Considerations,” may result in an installation less immune 

to damage caused by electrical disturbances, such as ESD or lightning, 

and may void the warranty.

Identify and connect the switch wires to the back box wires using the 

terminal block.

IMPORTANT!

  

The yellow wire is not a traditional traveler. It cannot directly 

power a lighting load. It must be used only to connect to a Control4 

Auxiliary Keypad. See “Sample Wiring Configurations.”

TIP:

  If you are using a Control4 push-on (screwless) faceplate in a multi-

gang installation, attach the black faceplate sub-plate to all of the devices 

that will be installed into the wallbox prior to attaching the devices to the 

wallbox. This will help ensure that all the devices are properly aligned and 

on the same plane after installation.

Fit the wires back into the back box. Bend the wires in a zigzag pattern so 

that they easily fold into the back box.

Align the switch to the back box (the load rating label should be at the 

bottom) and fasten it with screws. Tighten the screws until the back side of 

the yoke plate is even with the wall surface, but no further. Overtightening can 

warp the dimmer and cause mechanical malfunction.

Install the Control4 Faceplate following the instructions in the 

Faceplate 

Installation Guide 

or attach a standard Decora-style faceplate.

Turn ON mains power at the consumer unit.

Operation and configuration

On initial power up, all status LEDs on the switch will illuminate green indicating 

that the device has power. To set up this switch for use with a Control4 system, 

refer to the 

Composer Pro User Guide

To operate this switch as a stand-alone device:

• Click 

the 

top button

 to turn the light on.

• Click 

the 

bottom button

 to turn the light off.

Button tap sequences

Function

Button tap sequence  

(either top button only, or top-bottom-top)

Identify

4

ZigBee channel

7

Reboot

15

Factory reset

9-4-9

Leave mesh and reset

13-4-13

Troubleshooting

If the light does not turn on:

• 

Ensure at least one LED on the face of the switch is lit.

• 

Ensure the light bulb is not burned out and is screwed in tightly.

• 

Ensure that the circuit breaker is not turned OFF or tripped.

• 

Check for proper wiring (see “Sample Wiring Configurations”). 

• 

For help on the installation or operation of this product, email or call the 

Control4 Technical Support Center. Please provide your exact model number. 

Contact [email protected] or see the web site www.control4.com.

Care and cleaning

• 

Do NOT paint the switch or its wall plate.

• 

Do NOT use any chemical cleaners to clean the switch.

• 

Clean surface of the switch with a soft damp cloth as needed.

Regulatory/Safety information 

 

To review Regulatory information for your particular Control4 products, see 

the information located on the Control4 website at: http://www.control4.com/

regulatory/.

Patent information

Applicable patents are available at http://www.control4.com/legal/patents.

Warranty

For complete warranty information, including details on consumer legal rights as 

well as warranty exclusions, review the Warranty card or visit www.control4.com/

warranty.

About this document

Part Number: 200-00354 Rev C  3/12/2014  MS

Reviews: