![Contrel EMA-D9 User Manual Download Page 38](http://html1.mh-extra.com/html/contrel/ema-d9/ema-d9_user-manual_2658210038.webp)
EMA-D9 - USER MANUAL
-38-
10) SETUP
To accede in the setup pages press at the same time the LEFT and the RIGHT key. The main setup
menu is depicted in the following way:
Using the LEFT and the RIGHT keys to select each main setup page.
To enter in the first sub page to press the ENTER key in every above-mentioned pages and using the
LEFT and RIGHT key it’s possible to see the sub pages.
To enter in the page with there are the parameters to set, it’s necessary to press, in each sub page,
the ENTER key another time.
It’s possible to select every voice using LEFT, RIGHT, UP and DOWN keys depending of the situation.
The selected voice is indicated from the arrow
Æ
.
To modify the selected voice press ENTER key.
If the voice is a numeric field the first digit starts to flash. Use the UP and DOWN keys to modify this
digit or use LEFT and RIGHT key to change the digit selected.
If the voice belong at a group of voices, near the voice selected will appear one or two arrows.
it’s necessary to press the DOWN key to select others choices,
it’s necessary to press the UP key to select others choices,
it’s possible to press both the UP key and the DOWN key to select others choices.
To confirm the programming, use the ENTER key. The last modification will be stored in the memory
up to the new reset of system.
Warning. If the charge of the internal battery is very low, when the instrument is off it will loose the
setup configuration.
Warning: The instrument will loose the setup if it find some modification of hardware (insertion or
exclusion expansion module) when it is turning on.
Press at the same time the LEFT and the RIGHT key to exit from setup page. All of the time that these
keys are pressed the instrument will exit from the present page and it will pass at the following level
higher of setup. In the first level it’s possible to select the “EXIT” page and pressing ENTER to exit
from setup.
Setup
General
Setup
Serial Comm.
Setup
Average
Setup
Energy
Setup
Storage
Setup
Digital Output
Setup
Digital Input
Setup
Analog Output
Setup
Reset
Setup
Exit
CT
Enter
Enter
Enter
Enter
Mode - Warnings
Measure -Def.Page
Time
Blight - Access
Synchronization
Clock - Day Light
Out Index
Type
Measure Code
Value
Band Type
Inf-Sup Value
Enter
Time
Hysteresis
Reset
Measures
Reset Storage
Reset Setup
Reset Max
Demand
Enter
Reset Global
Enter
Communication
Protocol
Address
COM1
COM2
Type
Preset
Timebands
Enter
Storage
Min - Max
Storage
Average Power
Storage
Harmonics
Enter
Type
Set
Weights
Digital Input
Settings
Enter
Out Index
Type
Measure Code
Min - Max Value
Sync. Avg - Type
Time Avg-Dt Mobile
VT
Storage
Trigger
V Unbalance
Password