INSTALLATION PRECAUTIONS

1.

2.

The earth ground connection should be completed by a licensed electrician.

3.

Any separate fuel storage or Generator supply facility must be built or installed in

full compliance with all relevant local, state, and federal regulations.

5.

If the generator is installed outdoors, it must be weatherproofed and should be

soundproofed.  It should not be run outdoors without protection to the Generator

and wiring conduit.

6.

 Two or more people should assist when moving or lifting this product.  Never lift the

Generator using the engine or alternator lifting lugs. Connect lifting equipment

 to the Frame of the Generator.

7.

Before lifting the Generator, ensure the lift rigging and supporting structure are in

good condition, and are rated to lift such a load.

8.

Keep all personnel away from the suspended generator during relocating.

Warning: Never connect this generator to your house or any other structures 

wiring. 

This unit is not designed to be used as a standby generator to be wired to 

your electrical panel. It is designed to be used to provide power to either 120V or 

240V electrical devices by plugging the device into the generator. Failure to 

follow these instructions could lead to damage to appliances and the structures 

wiring that it is connected to.

4.

It is recommended to use the Generator only in well ventilated out-

door areas.  A running gasoline engine will generate Carbon Monox-

ide, a colorless, odorless gas that, if inhaled, can cause serious injury

or death.  

                   Generator exhaust fumes must be within legal limits and 

installation must always meet local building codes.

Summary of Contents for GEN03213

Page 1: ...8000W GENERATOR 8000W GENERATOR Stock No GEN8000 03213 Instruction Manual...

Page 2: ...tions operating inspec tion maintenance and cleaning procedures parts list and assembly diagram Keep your invoice with this manual Write the invoice number on the inside of the front cover Keep this m...

Page 3: ...ed in accordance with all codes and ordinances Never remove the grounding prong or modify the plug in any way Do not use any adapter plugs If the tools should electrically malfunction or break down gr...

Page 4: ...ain long hair Keep your hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving parts 12 Avoid accidental starting Make sure the Power Switch is in i...

Page 5: ...ous in the hands of untrained users 20 Maintain generators with care Do not use a damaged generator Tag dam aged generators Do not use until repaired 21 Check for misalignment or binding of moving par...

Page 6: ...e the lift rigging and supporting structure are in good condition and are rated to lift such a load 8 Keep all personnel away from the suspended generator during relocating Warning Never connect this...

Page 7: ...spills of fuel or oil occur they must be cleaned up immediately Dispose of fluids and cleaning materials as per any local state or federal codes and regula tions Store oil rags in a covered metal cont...

Page 8: ...While the Generator is running do not attempt to reach around the safety guards for maintenance or any other reason 5 Keep hands arms long hair loose clothing and jewelry away from moving parts Be awa...

Page 9: ...Feet 100 150 Feet 150 200 Feet 0 5 16 16 16 12 12 5 1 8 16 16 14 10 8 1 12 14 14 12 12 1 15 12 12 10 15 1 20 10 10 10 20 47 6 FIGURE A 4 Do not attempt to connect or disconnect load connections while...

Page 10: ...tools and or equipment for connection to a separate Generator 2 WARNING The Generator weighs approximately 181 pounds Use care and the proper lifting or hoisting equipment when moving it to the instal...

Page 11: ...11 OPERATING INSTRUCTIONS NOTE For additional references to the parts listed in the following pages refer to the Assembly Diagrams on pages 19 and 21 Pre Start Checks 1 Check to make sure the Engine...

Page 12: ...PAGE 12 GROUND CONNECTOR 8 6AWG GROUNDING WIRE NOT INCLUDED GROUNDING ROD NOT INCLUDED FUELTANK 30 33 POWER SWITCH 2...

Page 13: ...the Fuel Tank with unleaded gasoline the Generator must be turned off and cooled down before refilling the fuel tank See Figure C To Start The Engine 1 Make sure the electrical powered tools equipmen...

Page 14: ...llow the gasoline to flow into the Engine s carburetor Then hold the Start Handle firmly and pull the rope hard and fast Pull the rope all the way out using two hands if necessary If necessary pull th...

Page 15: ...n only one of the breakers will cause the unit to only put out 1 2 of the total output See Figure G NOTE The Generator features AC Non Fuse circuit breakers 5 to protect the AC circuit in case of an o...

Page 16: ...Figure H 4 Start and run the Engine as previously discussed in this manual 5 When finished using the Generator turn the Engine Power Switch 2 to its OFF position Turn the Fuel Valve 40 to its OFF posi...

Page 17: ...use drain the old Engine oil and replace with approximately 3 4 0 63 quart of a high quality SAE 10W 30 grade engine oil 6 Every 300 hours of use have a qualified certified technician perform thoroug...

Page 18: ...PARTS LIST PAGE 18 NOTE Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts 2...

Page 19: ...PAGE 19...

Page 20: ...PARTS LIST A NOTE Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts PAGE 20 Oil Sensor Nut Oil Sensor...

Page 21: ...ASSEMBLY DIAGRAM A PAGE 21...

Page 22: ...WIRING DIAGRAM PAGE 22...

Reviews: