Prior to powering tools and equipment, make sure the Generator's rated voltage, and
amperage capacity
(120V 47AMP, 240V 23AMP)
is adequate to supply all electrical
loads that the unit will power. If powering exceeds the Generator's capacity, it may be
necessary to group one or more of the tools and/or equipment for connection to a
separate generator.
Once the generator is running select the desired voltage with the voltage selector
switch located below the voltmeter, then simply connect the power cords to the
correct outlet and turn on both breakers.
Warning, turning on only one of the
breakers will cause the unit to only put out 1/2 of the total output.
(See Figure G.)
NOTE:
The Generator features AC Non Fuse circuit breakers (5) to protect the AC
circuit in case of an overload occur the Breaker will "trip" to its
"OFF"
position. In this
case, refer to Step #1 above in this section. Then, reset the circuitry system by
turning the circuit Breaker to its
"ON"
position. Restart the Generator and continue
powering the remaining tools and equipment.
(See Figure D.)
When finished using the generator, shut the circuit breakers off and then turn the
engine power switch to its
"OFF"
position. Turn the Fuel valve to its
"OFF"
position.
Then, disconnect all electrical powered tools and equipment from the Generator's
120 volt AC Duel Outlets (6).
(See Figures E, F, and G.)