13
CONTRACOR
®
DBS Art. 10100/10200
ENGLISH
6.3. Set Up and Installation.
1.
The vessels can be set up indoors or outdoors under a roof.
Safety-regulations and standards and fire-regulations and standards, depending on
the media used, must be observed when choosing a place for setup. When set up
outdoors, the minimal and maximum working temperatures must be observed.
2.
The vessels have to be installed in such a way that they and all fittings and parts are
accessible for inspections, tests, maintenance and cleaning, from the inside and the
outside.
The type plate has to be accessible and kept clean so that it is readable at all times.
3.
The main body is based on supports, stands or feet suitable for the strain of the
pressure test. The vessel must be set up on foundations with a stability suitable for
the strain of the pressure test.
6.4. Setting the Vessel to Work.
A. Conditions for setting the vessel to work.
1.
The vessel can be set to work, including test operation, if:
— its condition does not pose a danger to people and environment,
— the system and equipment is complete, tested and meets the requirements
according to the documentation and applying standards.
B. Procedure before start up of the machine
2.
Before closing the vessel make sure that there is no foreign matter or object inside.
3.
Make sure that all inspection doors and flanges have the correct number of bolts,
that the bolts are inserted correctly in place and of the right length and tightened to
the correct torque.
Summary of Contents for DBS-100
Page 4: ...4 CONTRACOR Version 2 0 ENGLISH 2 General view...
Page 11: ...11 CONTRACOR DBS Art 10100 10200 ENGLISH Fig 5 1...
Page 20: ...DEUTSCH 20 CONTRACOR Version 2 0 2 Ansicht Arbeitsaufbau...
Page 27: ...DEUTSCH 27 CONTRACOR DBS Art 10100 10200 Abb 5 1...
Page 35: ...35 CONTRACOR DBS Art 10100 10200 1 37 2 38 3 40 4 42 5 44 6 46...
Page 36: ...36 CONTRACOR 2 0 1 1 2 3 4 5 6...
Page 37: ...37 CONTRACOR DBS Art 10100 10200 2...
Page 39: ...39 CONTRACOR DBS Art 10100 10200 3 3 1 1 2 3 4 5 6 FSV 7 1 25 8 9 10...
Page 40: ...40 CONTRACOR 2 0 3 2 1 12 2 3 4 FSV 5 3 3 1 2...
Page 41: ...41 CONTRACOR DBS Art 10100 10200 4 4 1 4 2...
Page 42: ...42 CONTRACOR 2 0...
Page 44: ...44 CONTRACOR 2 0 5 1...
Page 45: ...45 CONTRACOR DBS Art 10100 10200 6 1 CONTRACOR 12 2 3 4 5 6 7 8 9...