Important Note:
Never use harsh detergents, cleaners, scouring powders or
chemicals when cleaning your model. Failure to dry the interior surfaces after
cleaning may result in a streaking or staining of the metal.
Complete cleaning procedures and precautions are listed in the “periodic cleaning
procedure” under the maintenance section.
START-UP PROCEDURE
ELECTRICAL CONNECTIONS
To insure proper operation, your new model must be connected to an individual
circuit that can supply the full voltage as stated on the cabinet serial data plate.
For correct voltage, power draw, and wire accommodations, check the data on the
serial data plate located on the inner right wall of your new model. Verify that this
information exactly matches the electrical characteristics at the installation location.
An electrical wiring diagram, located on the inside compressor compartment rear,
next to the electrical console box, should also be consulted during connection. For
reference, a copy of each electrical wiring diagram is located at the rear of this
manual in the “maintenance” section.
Important Note:
The condensing unit supplied with all self-contained models is
designed to operate with a voltage fluctuation of + 10 % of the voltage indicated
on the cabinet serial data plate. Full voltage of the correct service, on an individual
line not affected by the operation of other electrical appliances, must be available
to the condensing unit at all times. Burnout of the compressor due to exceeding the
high or low voltage limits is easily detected and will automatically void the factory
warranty.
115 VOLT, 60 HZ, 1 PHASE CONNECTION
All 115 volt models are provided with a U.L. approved power cord and polarized
plug which is factory installed.
Warning:
Any alterations to this cord and plug could cause an electrical
hazard and will void the factory warranty.
To insure proper operation, this equipment must be plugged into a NEMA 5-15r
compatible, grounded receptacle that can supply the full voltage as stated on the
serial data plate.
13