ELECTRONIC CONTROL FOR REFRIGERATORS, FREEZERS AND WARMERS
OPERATIONS MANUAL
ELECTRONIC CONTROL USER LEVEL PARAMETERS
User level parameters give the end user the option to customize their control.
TO ACCESS AND CHANGE USER LEVEL PARAMETERS
•
Press and HOLD the “SET” button until “PS” appears
flashing in the display. RELEASE the “SET” button.
You now have access to the User Parameters.
•
Use the “UP” or “DOWN” button to go to the
parameter.
•
Press and RELEASE the “SET” button to access
the parameter settings.
•
Use the “UP” or “DOWN” button to change the
parameter value.
•
Press and HOLD the “SET” button for 5 seconds to lock in the new value.
•
When the display returns back to cabinet temperature, RELEASE the “SET” button.
Parameter Description
PS
Password used to access tech service parameters Used by service personnel to
access tech service parameters
/C1
Display probe offset value
Used to calibrate the
temperature display
dl
Defrost interval
Hours between defrost. The
lower the value, the more
defrosts per day.
AL
Low temperature alarm setting
Used to set the low temperature
alarm value.
AH
High temperature alarm setting
Used to set the high temperature
alarm value.
H4
Alarm beeper
0: Beeper active
1: Beeper not active
For a more detailed description on how to access and change these parameter values, there are
individual pages in this manual with detailed instructions.