OPERATIONS MANUAL
SPLIT CONTROL PARAMETERS
Par. Description
Level Unit Set
Set
Set
Set
Set
Set
Set
Set
Set
Set
/2 measurement stability: lower quicker resp
PW
-
4
4
4
4
4
4
4
4
4
4
/3 probe display response: lower quicker resp
PW
-
1
1
1
1
1
1
1
1
1
1
/4 probe display select 1: box 2: evap 3: amb
PW
-
1
1
1
1
1
1
1
1
1
1
/5 units in °C (0) or °F (1)
PW
-
1
1
1
1
0
1
1
1
1
1
/6 decimal display (0) or not (1)
PW
-
1
1
1
1
0
1
1
1
1
1
/C1 probe 1 offset (display)
User
°F
2.5
2.5
2.5
1.2
1.4
1.2
0
1.2
2.5 10.0
/C2 probe 2 offset (evap)
PW
°F
1
1
1
1
0.6
1.2
0
1
1
1
/C3 probe 3 offset (ambient)
PW
°F
0
0
0
0
0
0
0
0
0
0
St set point (cutout)
User
°F
-2
-10
-15
26
-18.9
36
36
26
-3
-2
rd differential (positive dif)
PW
°F
5
5
5
4
2.8
4
3
4
6
5
r1 minimum set point allowed
PW
°F
-10
-18
-18
20
-23.3
32
32
20
-10
-10
r2 maximum set point allowed
PW
°F
15
15
15
40
-9.4
40
40
40
15
15
FH FH enabled
PW
-
1
1
1
1
1
2
2
2
1
1
FHt fascia heater threshold: temp heaters turn on
PW
°F
80
80
80
80
26.7
80
80
80
80
80
FHd fascia heater differential
PW
°F
1
1
1
1
1
1
1
1
1
1
c0 comp and fan start delay power up
PW
min
1
1
1
1
1
1
1
1
1
1
c1 min time between starts
PW
min
2
2
2
2
2
3
3
2
2
2
c2 min comp off time
PW
min
1
1
1
1
1
1
1
1
1
1
c3 min comp on time
PW
min
1
1
1
1
1
2
2
1
1
1
c4 compressor on time with duty cycle
PW
min
14
15
15
8
14
6
6
8
14
14
d0 type of defrost
PW
-
0
0
0
0
0
0
0
0
0
0
dl interval between defrosts
User
hr
6
8
8
8
8
6
6
8
8
8
dt end defrost temperature
PW
°F
50
50
50
44
10
40
44
44
50
50
dP max defrost duration
PW
min
30
30
30
20
30
40
40
20
30
30
d6 display during defrost (1: temp 2: DF)
PW
-
1
1
1
1
1
1
1
1
1
1
dd dripping time
PW
min
3
3
3
3
3
0
0
3
3
3
d8 alarm bypass after defrost
PW
hr
2
2
2
2
2
2
2
2
2
2
d/ display defrost probe (displays def temp)
PW
°F
-
-
-
-
-
-
-
-
-
-
A0 alarm and fan differential
PW
°F
-10
-10
-10
-10
-5.6
-2
-2
-10
-10
-10
AL low temp alarm
F
°F
-20
-20
-25
15
-28.9
30
30
15
-20
-20
AH high temp alarm
F
°F
40
40
40
50
4.4
50
50
50
40
40
Ad temp alarm delay
PW
min
60
60
60
60
60
60
60
60
60
60
A4 third input config (0: not used 13: amb probe)
PW
-
13
13
13
13
13
0
0
0
13
13
C8IA41 UPRIGHT FRZR, SWF
1.215/.216
REV. 5/21/2019
C8IA41>-10D UPRIGHT FRZR -10F
C8IA41>-15D UPRIGHT FRZR -15F
C8IA41>28D UPRIGHT FRZR 28F
C8IA41>CEL UPRIGHT FRZR CELSIUS
C8IA41>38D SW SOLID TOPS
C8IA41>38DOT SW OPEN TOPS
C8IA41>28DNH SW SOLID TOP 28F
C8IA41>EFC 1FS, 1FSE, DL1FS, DL1FSE
C8IA41>CFA CFA MODELS