Form No. 265283    Rev. 07/08

Operation (Continued...)

3

PVR15-30B KIT LIST 

(Refer to Drawing and Parts List)

 

 

WEAR PLATE KITS

 Includes Items:  4 & 5

  

Model 

 

Kit Number

  

30B 

 

252933

 

 

 

SEAL KITS

 Includes Items:  13,14,15,16,17,24,25,85,86,99

  

Model 

 

Kit Number

  

All Buna-N 

 

250008

  

All Viton 

 

250009

  

  

 

VANE KITS

  

Includes Items:  7

 

Model 

 

Kit Number

 

30B 

 

252932

 

 

ROTATING KITS

 Includes Items:  3, 6 & 21

  

Model 

Code 

Kit Number

  

30B 

 

Consult Factory

  

30B 

12 

252935

  

30B 

21 

Consult Factory

  

30B 

22 

Consult Factory

 

 

COMPLETE REBUILD KITS

 Includes Items:  All Kits Listed Here Plus Items 11 & 22

  

Model 

Code 

Kit Number

  

30B 

 

252899

  

30B 

12 

252938

  

30B 

21 

254999

  

30B 

22 

255002

A pressure gauge located at the pump must be used 

when making adjustment to insure the pressure 

settings do not exceed limits specified for the 

particular pump of maximum system pressure.

Make all pressure settings with pump operating 

against a closed circuit, that is with the output of the 

pump blocked, and then check pressure throughout 

the pump flow range.

Volume Control

Adjust volume at minimum pump pressure or at pump 

deadhead.  The volume adjusting screw is directly 

opposite the pressure adjusting screw, see parts page 

item number 55.  The adjusting screw has a right 

hand thread, turning the screw clockwise decreases 

the maximum volume, turning the screw 

counterclockwise increases the maximum volume.  

Pumps are set at a maximum rated volume at the 

factory unless otherwise specified.

  

Stop adjustment of the volume screw when pressure 

begins to drop.  See Sales Catalog for complete 

pump performance specifications.

ADJUSTMENT PROCEDURES

To adjust the maximum output volume use the 

following steps:

1.  Set the pump at minimum pressure.

2.  Hand tighten the volume screw until it touches 

pressure ring. 

NOTE:

 The pump should be at full flow 

for this step.

3.  See Pressure and Volume Adjustment Sensitivity 

chart below.

4.  Deadhead the pump, turn the volume screw the 

proper number of turns to obtain the flow desired.

5.  Return pump to flow condition and check flow rate.  

If output flow is incorrect, switch pump to deadhead 

and readjust. 

 

CAUTION -

 Turning the maximum volume  

 

control in too far can force the pressure ring  

 

over-center and destroy the pump.

Pressure and Volume Adjustment Sensitivity

 

 

            

 PUMP SIZE 

30B

 

 

Pressure

 

psi 

240 

 

Pressure  Change/Turn

 

(bar) 

(16.5) 

 Adjustment  Maximum

 

ft.-lbs. 

2.7 

 

 

Torque

 

(m-kg) 

(0.37)

 

 

Flow

 

gpm 

4.6 

 

 

Change/Turn

 

(lpm) 

(17.4) 

  Volume 

Approx. Min.

 

gpm 

1.0 

 

Adjustment  Flow Adjust.

 

(lpm) 

(3.7) 

 

 

Maximum

 

ft.-lbs 

3.5 

 

 

Torque

 

(m-kg) 

(0.48)

Summary of Contents for PVR15-30B-Flanged Series

Page 1: ...ith belt drives please consult factory To avoid axial and radical end loading of the pump shaft do not couple the pump and motor shafts rigidly Allow freedom at the coupling for the two shafts to ride...

Page 2: ...e drain return 5 Rotate pump and motor by hand to insure free rotation 6 Set the machine controls to open the circuit and allow free flow from the pump back to tank or connect the pump outlet line dir...

Page 3: ...ng screw see parts page item number 55 The adjusting screw has a right hand thread turning the screw clockwise decreases the maximum volume turning the screw counterclockwise increases the maximum vol...

Page 4: ...ndwheel 1 39 36 261323 Spring Pin 1 40 004223 Spring Pin 1 ITEM CODE PART DESCRIPTION QTY N0 NO REQ 43 122975 Shim 010 A R 44 15 301737 Handwheel 1 45 15 004262 Spring Pin 1 50 Valve Refer to Valve Es...

Page 5: ...RTS DRAWING 44 45 30 8 10 43 41 9 11 12 40 39 38 55 13 15 5 6 3 4 17 23 2 23 14 16 22 21 18 95 7 93 20 25 19 67 24 21 1 66 See Page 6 for Control Options PVR15 30B PARTS DRAWING Codes 12 21 22 31 Tand...

Page 6: ...ual Volume Control Without Integral Valve Code 24 Dual Volume Control With Integral Valve Code 2500 Dual Pressure Volume Control Without Integral Valve Code 25 Dual Pressure Volume Control With Integr...

Page 7: ...an expanding type puller The bushings should not be reused once they have been removed 11 It is unlikely that further disassembly will be necessary in order to perform routine maintenance on the pump...

Page 8: ...housing to the depth shown below Note the lip to the inside orientation of the seals 13 Adjust the pressure adjustment screw 30 until it just touches the spring and then give it one more turn clockwis...

Reviews: