PVR15-30B PUMP REPAIR PROCEDURES

DISASSEMBLY PROCEDURE

NOTE:  Disassembling a pump to change 

components, or for any other reason, may void the 

warranty.  Refer to Policy Statement and Discounts 

Summaries.

1.  Remove the key (22) in the rotor shaft keyway.

2.  A small amount of oil may remain in the pump.  

Remove the four cover bolts (18) and slide the cover 

back far enough on the shaft to break the seal 

between the housing and cover to allow the pump to 

drain.

3.  Remove the cover (2).  Take care to avoid damage 

to the bearing with the end of the shaft when the 

cover is removed.

4.  The port plate (4) may come out with the cover. Do 

not let it drop off the locating pins (23).

5.  Remove the vanes (7) with a long nosed pliers or 

tweezers.  There are two vanes in each slot, 26 vanes 

total.

6.  Remove the rotorshaft (3) from the pump.  Be sure 

that the key (22) has been removed from the keyway 

so that it will not damage the shaft seals when the 

rotorshaft is removed.

7.  Turn the pressure adjustment screw (30) 

counterclockwise to release the tension on the 

governor spring.

8.  Remove the pressure ring (6), ring shoe (11), 

governor spring (9), spring retainer (41) and follower 

spring (10).

9.  If the lip seals (24) are to be removed they should 

be pushed out from the inside of the housing at this 

time.  Care must be taken not to damage the journal 

bushing in the housing while the lip seals are being 

removed.  It is recommended that the lip seals be 

replaced whenever the pump is disassembled for 

maintenance.  The seals cannot be reused once they 

have been removed.

10. The journal bearings (21) in the pumps are 

assembled with a press fit.  If they are to be removed 

at this time, the bushing in the housing should be 

pressed out from the front.  The cover bushing should 

be pulled out using an expanding type puller.  The 

bushings should not be reused once they have been 

removed.

11. It is unlikely that further disassembly will be 

necessary in order to perform routine maintenance on 

the pump.

REASSEMBLY PROCEDURE

1.  Clean and inspect parts to determine which parts 

are worn enough to require replacement.

2.  Assemble the new journal bushings (21) in the 

housing and cover.  The bushing OD's should be 

lubricated before they are pressed in the bores.  Care 

must be taken to orient the "split" and the "oil groove" 

in the bushing as shown in the illustration below.

3.  After the bushings are in place, check to see that 

the rotorshaft will fit into the bushings and provide a 

smooth turning fit.  If the shaft turns hard, the 

bushings should be removed and the bore checked 

closely for nicks or burrs before pressing in the new 

bushings.

4.  Check all of the replacement parts for nicks or 

burrs and then lubricate them with clean oil before 

reassembly.

5.  Worn port and thrust plates should not be 

reground to clean up the wear surface.  If the plates 

are ground, the assembly clearance will become 

excessive and the seal rings in the thrust plate may 

rupture.  Replace worn port and thrust plates if 

necessary.

6.  Assemble the springs (9, 10) and spring shoe (11), 

pressure ring (6) and rotorshaft (3).

7.  To assure proper vane assembly, place the vanes 

(7) with the beveled edge out against the pressure 

ring. 

8.  Assemble the four seal rings into the cavity in the 

back of the thrust plate.  The soft rubber o-rings (14, 

16) should be assembled first and the hard square 

seal rings (13, 15) should be assembled on top of 

them.  Stretch the larger soft o-ring slightly so it clings 

to the ID at the cavity.  Apply clean oil or STP to the 

back of the thrust plate before it is placed in the 

Spring Housing

C

L

C

L

Oil Groove Position

Thrust

Screw

Item #21

Journal Bushing Orientation

7

Form No. 265283    Rev. 07/08

Pressure Ring

Rotor Shaft

Vane

Item #7

Typical Vane Installation

Summary of Contents for PVR15-30B-Flanged Series

Page 1: ...ith belt drives please consult factory To avoid axial and radical end loading of the pump shaft do not couple the pump and motor shafts rigidly Allow freedom at the coupling for the two shafts to ride...

Page 2: ...e drain return 5 Rotate pump and motor by hand to insure free rotation 6 Set the machine controls to open the circuit and allow free flow from the pump back to tank or connect the pump outlet line dir...

Page 3: ...ng screw see parts page item number 55 The adjusting screw has a right hand thread turning the screw clockwise decreases the maximum volume turning the screw counterclockwise increases the maximum vol...

Page 4: ...ndwheel 1 39 36 261323 Spring Pin 1 40 004223 Spring Pin 1 ITEM CODE PART DESCRIPTION QTY N0 NO REQ 43 122975 Shim 010 A R 44 15 301737 Handwheel 1 45 15 004262 Spring Pin 1 50 Valve Refer to Valve Es...

Page 5: ...RTS DRAWING 44 45 30 8 10 43 41 9 11 12 40 39 38 55 13 15 5 6 3 4 17 23 2 23 14 16 22 21 18 95 7 93 20 25 19 67 24 21 1 66 See Page 6 for Control Options PVR15 30B PARTS DRAWING Codes 12 21 22 31 Tand...

Page 6: ...ual Volume Control Without Integral Valve Code 24 Dual Volume Control With Integral Valve Code 2500 Dual Pressure Volume Control Without Integral Valve Code 25 Dual Pressure Volume Control With Integr...

Page 7: ...an expanding type puller The bushings should not be reused once they have been removed 11 It is unlikely that further disassembly will be necessary in order to perform routine maintenance on the pump...

Page 8: ...housing to the depth shown below Note the lip to the inside orientation of the seals 13 Adjust the pressure adjustment screw 30 until it just touches the spring and then give it one more turn clockwis...

Reviews: