background image

3

Form No. 253585   Rev. 

04/19

The pressure adjusting screw is located at the end 

face of the compensator chamber.  See parts page 

item number 30.  The adjusting screw has a right 

hand thread; clockwise adjustment of the screw 

increases the pressure; counterclockwise adjustment 

reduces the pressure.

A pressure gauge located at the pump must be used 

when making adjustments to ensure the pressure 

settings do not exceed limits specified for the 

particular pump or maximum system pressure.

Make all pressure settings with the pump operating 

against a closed circuit, that is with the output of the 

pump blocked, and then check pressure throughout 

the pump flow range.

Volume Control Adjustment

Adjust volume at minimum pump pressure or at pump 

deadhead.  The volume adjusting screw is directly 

opposite the pressure adjusting screw, see parts page 

item number 55.  The adjusting screw has a right 

hand thread, turning the screw clockwise decreases 

the maximum volume, turning the screw 

counterclockwise increases the maximum volume.  

Pumps are set at maximum rated volume at the 

factory unless otherwise specified.

Stop adjusting the volume screw when pressure 

begins to drop.  See Sales Catalog for complete 

pump performance specifications.

ADJUSTMENT PROCEDURES

To adjust the maximum output volume, use the 

following steps:

1. Set the pump at minimum pressure.

2. Hand-tighten the volume screw until it touches the

pressure ring. 

NOTE:

 The pump should be at full flow

for this step.

3. See Pressure and Volume Adjustment Sensitivity

chart below.

4. Deadhead the pump, then turn the volume screw

the proper number of turns to obtain the flow desired.

5. Return pump to flow condition and check flow rate.

If the output flow is incorrect, switch pump to

deadhead and readjust per above.

CAUTION -

 Turning the maximum volume  

control in too far can force the pressure ring 

  over-center and destroy the pump.

PRESSURE and VOLUME ADJUSTMENT SENSITIVITY

PUMP SIZE 

4B 

6B 

8B 

PRESSURE CODE 

10 

15 

03 

06 

10 

03 

06 

10

 

PRESSURE  Press Change/Turn

  psi (bar)  255 (17.8)  270 (18.6)  115 (7.9)  210 (14.5)  240 (16.5)  115 (7.9)  210 (14.5)  240 (16.5) 

ADJUSTMENT  Max.Torque

 

ft./lbs.(kg/m)  4.0 (0.55)  6.0 (0.83)  1.4 (0.19)  2.6 (0.36)  4.0 (0.55)  1.4 (0.19)  2.6 (0.36)  4.0 (0.55)

VOLUME 

Flow Change/Turn

  gpm (lpm) 

 3.4 (12.5) 

4.6 (17.4) 

4.6 (17.4) 

 ADJUSTMENT  Min. Flow Adjust.

  gpm (lpm) 

 1.25 (4.7) 

1.25 (4.7) 

1.25 (4.7) 

 

 

Max. Torque

 

ft./lbs. (kg/m) 

 2.5 (0.34) 

1.0 (0.14) 

1.0 (0.14)

Summary of Contents for PVR1 Series

Page 1: ...ANGES Design Series A thru G used a 406 woodruff key nominally 1 8 inch 3 2 mm wide Design Series H and later use a common 3 16 x 3 16 x 1 inch square key When replacing older pumps with a newer one i...

Page 2: ...mp will be deadheading for long periods of time during operation using a full size line corresponding to the case drain in the pump or manifold If connected to a heat exchanger the case drain line sho...

Page 3: ...otherwise specified Stop adjusting the volume screw when pressure begins to drop See Sales Catalog for complete pump performance specifications ADJUSTMENT PROCEDURES To adjust the maximum output volu...

Page 4: ...585 Rev 04 19 40 45 45 46 46 55 19 24 21 1 11 9 10 30 8 25 20 23 4 6 59 16 58 39 3 5 15 80 21 2 66 22 7 13 17 18 67 31 4B Only 22 34 32 33 24 3 2 66 67 PVR1 PARTS DRAWINGS For PVR1 6B Code 13 Tandem M...

Page 5: ...E PART DESCRIPTION QTY NO NO REQ D 22 126225 Key Add 1 Code 13 6B 1 23 004223 Roll Pin 2 24 130795 Lip Seal Add 1 Code 13 1 6B 25 104617 O Ring 1 25 Viton 166069 O Ring 1 30 309977 Pressure Adj Screw...

Page 6: ...0 The bearing bushing 21 in the pumps are assembled with a press fit If they are to be removed at this time the bearing in the housing should be pressed out from the front The cover bearing should be...

Page 7: ...over 2 and thrust plate 5 onto the housing 1 and align the bolt holes Rotate the shaft as the cover bolts 18 are tightened to assure that the vanes are not cocked 12 Torque the cover bolts to 50 lbs f...

Page 8: ...s specifications and appearance are subject to change without notice Form No 253585 Rev 04 19 2008 Continental Hydraulics Printed in U S A Continental Hydraulics 5505 West 123rd Street Savage MN 55378...