W415-1112 / 06.12.12
33
required ComPonenTS: • CHmf150/200 Hybrid furnace
• Hmfk-bmP50 blower box module
• Hmfk-ef15, -ef18, -ef20, -ef23, -ef25, -ef30, electric furnace module
(HMFK-EF23, -EF25, -EF30 are available for the CHMF200 only)
• Hmfk-Solid or Hmfk-GlaSS door kit
STEp #5
○ Completely assemble CHmf150/200 in required left or right hand
"ra" configuration as required.
○ locate and level CHmf150/200 while maintaining minimum 1.25" (32
mm) clearance space between bottom of furnace and floor.
○ use the levelling legs to compensate for uneven floor and snug the
lock nuts up to furnace base to prevent movement through vibration.
STEpS #1 - #4
Follow Steps 1 to 4 from SECTION 5.1 - HYBRID CHMF150/200 AS AN "ADD ON" TO EXISTING FURNACE.
STEp #6
○ remove contents of the blower module kit and compare with contents list on "manual" addendum accom-
panying the blower module.
STEp #7
○ remove contents of the electric furnace module kit and compare with contents list on "manual" addendum
accompanying the electric furnace module.
STEp #8
○ Place the blower module and the electric furnace module beside each other as per diagram:
loCk nuT
level leG
eleCTriC furnaCe
ConTrolS
eleCTriC furnaCe
module
bloWer HouSinG
module
LEFT HAND RA CONFIgURATION
RIgHT HAND RA CONFIgURATION
○ align holes in the adjacent top and side flanges, and
secure with 9 x ¼" hex head wildrill screws.
NOTE
Top/bottom flange screws
thread into blower. Side
flange screws thread into
electric unit.
STEp #9
○ Place the open side of electric furnace against rectangular inlet window on the side panel of CHmf150/200
furnace. adjust the levelling legs on the blower box module so that the electric furnace module is level and
holes on the mounting flanges align with pilot holes on side of furnace panel.
5.4 HyBrId CHmF150/200 AS A COmBINATION “wOOd/ELECTrIC” FurNACE