OIL FURNACE
MODULE
PROTECTIVE
COVER
NOTCHED RELIEF
CABLE STRAPS
HARNESS "C"
LOWER
ELECTRICAL
BOX
(CHMF150/200
ELECTRICAL
HARNESS)
LEFT HAND RA CONFIGURATION
RIGHT HAND RA CONFIGURATION
OIL FURNACE
MODULE
PROTECTIVE
COVER
NOTCHED RELIEF
CABLE STRAPS
HARNESS "C"
LOWER
ELECTRICAL
BOX
(CHMF150/200
ELECTRICAL
HARNESS)
○
Route Harness "C" between oil burner and lower electrical box of CHMF150/200 electrical harness.
○
Match and connect harness connectors "C" inside the lower electrical box and snap
fl
ex conduit connector
into side of electrical box.
○
Flex conduit shall be secured along bottom edge of side panel by screwing cable straps over
fl
ex conduit -
use dimples provided to locate screws holding cable straps.
○
Wires from other end of harness should pass through appropriate bulk head on frame of oil burner, and the
fl
ex conduit shielding secured to the bulk head by the 90°
fl
ex connector. Connector should be secured
from other side of bulk head by connector nut.
○
Power, neutral and ground connections should be made to oil burner controls as per installation/owner
manual for speci
fi
c oil burner.
○
Flex conduit should be secured to
fl
oor where conduit passes under the oil furnace modules protective
cover. The
fl
ex conduit should pass directly below the notched relief in the side of the protective cover.
STEP #15
NOTE
Wire harness “C”, which runs from junction box and oil furnace burner, has been supplied at the length
required for a right hand RA con
fi
guration. If installing oil furnace with a left hand RA con
fi
guration, the wires
in the harness and the
fl
ex conduit will have to be shortened by approximately 12” (305mm). Attach harness
to junction box and secure conduit on CHMF150/200 to determine actual length of wires and
fl
ex conduit.
H3.45
ALL 115V ELECTRICAL PRE ASSEMBLED HARNESSES MUST BE INSTALLED AS PER
INSTRUCTIONS.
NO 115V ELECTRIC CIRCUIT HARNESS OR FIELD WIRING MAY PASS THROUGH CLEARANCE
SPACE BETWEEN HMF150/200 FURNACE BOTTOM AND FLOOR.
FAILURE TO COMPLY MAY RESULT IN ELECTRIC SHOCK, FIRE, PROPERTY DAMAGE OR
PERSONAL INJURY.
W415-1506 / A / 12.04.15
28
IOM
EN