4.8 MINIMUM CLEARANCE TO COMBUSTIBLES
MINIMUM CLEARANCES TO COMBUSTIBLES (FROM THE APPLIANCE):
-
11” (279mm) to top
-
7” (178mm) to sides
-
0” (0mm) to bottom
-
0” (0mm) to rear
* A minimum of 1” (25mm) all around the vent pipe on all vertical runs to combustibles is required.
TYPICAL
INSTALLATION
ALCOVE
INSTALLATION
SIDE VIEW
The front trims for the CWHD31 are different sizes. See “DIMENSIONS” section prior to mounting the
appliance.
MINIMUM CLEARANCE TO COMBUSTIBLE CONSTRUCTION FROM APPLIANCE AND VENT
SURFACES:
-
0” (0mm) to wall mounting plate
-
1” (25mm) to bottom and sides of vent pipe*
-
2” (51mm) to top of vent pipe*