8

W415-0895 / C / 03.13.12

2.4  RATING PLATE INFORMATION

INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to 
the model, venting and gas type of the appliance.

For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.

W385-0497 / D

&(57,),('81'(5+202/2*8(6(/21/(61250(6$16,=E‡&6$E9(17('*$6),5(3/$&()2<(5$8*$=9(17,/e

DIRECT VENT GAS FIREPLACE HEATER. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING 
ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE 
WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, 
IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND 

6$)(7< 67$1'$5' 7,7/(  &)5 3$57  :+(1 7+,6 86 67$1'$5' ,6 127
$33/,&$%/(86(7+(67$1'$5')25),5(6$)(7<&5,7(5,$)250$18)$&785('+20(

INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. THIS APPLIANCE MUST BE 

,167$//(',1$&&25'$1&(:,7+/2&$/&2'(6,)$1<,)121()2//2:7+(&855(17

ANSI Z223.1, OR CSA B149, INSTALLATION CODES.

)2<(5'(&+$8))$*($8*$=$9(&e9$&8$7,21+202/2*8e3285,167$//$7,21'$1681(
&+$0%5( ¬ &28&+(5 81( 6$//( '( %$,1 (7 81 678',2$335235,e 3285 ,167$//$7,21

DANS UNE MAISON MOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA 

1250(&$1&6$=0+6e5,('(0$,621602%,/(6e48,3e(6$8*$=(19,*8(85$8
&$1$'$ 28 $8; e7$7681,6 '( /$ 1250( '( 6(&85,7e (7 '( &216758&7,21 '(
0$,62160$18)$&785e(67,75(&)56(&7,21'$16/(&$628&(77(1250(
'e7$7681,61(3(87Ç75($33/,48e(6(5e)e5(5$/$1250(5(/$7,9($8&5,7Ê5(
'( 0(685(6 '( 6e&85,7e &2175( /,1&(1',( 3285 /(6 ,167$//$7,216 '$16 /(6
0$,6216 0$18)$&785e6 /(6 6,7(6 (7 /(6 &20081$87e6$16,1)3$ $ &2'(6
,167$//(5/¶$33$5(,/6(/21/(6&2'(6285Ê*/(0(176/2&$8;28(1/¶$%6(1&(
'(7(/65Ê*/(0(1766(/21/(6&2'(6'¶,167$//$7,21$16,=28&6$%(1

VIGUER.

 

9700539 (WSL) 

 

4001657 (NGZ) 

 4001658 

(NAC) 

 

4001659 

(WUSA)

 LHD45N CLHD45N 

MODEL 

CLHD45P 

LHD45P

 

 

)7P

$/7,78'(e/e9$7,21

)7P

 

 

24,000 BTU/h 

INPUT / ALIMENTATION 

24,000 BTU/h

3.5" WATER COLUMN/D'UNE COLONNE D'EAU 

MANIFOLD PRESSURE/PRESSION AU COLLECTEUR: 

 

10" WATER COLUMN/D'UNE COLONNE D'EAU 

4.5" WATER COLUMN/D'UNE COLONNE D'EAU 

MINIMUM SUPPLY PRESSURE/PRESSION D'ALIMENTATION MINIMALE:

 

11" WATER COLUMN/D'UNE COLONNE D'EAU

7.0" WATER COLUMN/D'UNE COLONNE D'EAU 

MAXIMUM SUPPLY PRESSURE/PRESSION D'ALIMENTATION MAXIMALE:

 

13" WATER COLUMN/D'UNE COLONNE D'EAU

NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS 
DOORS CERTIFIED WITH THIS UNIT ONLY.

WARNING: 

'2127$''$1<0$7(5,$/727+($33/,$1&(:+,&+:,//&20(

IN CONTACT 

:,7+7+()/$0(627+(57+$17+$76833/,('%<7+(0$18)$&785(5:,7+7+($33/,$1&(

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /

'e*$*(0(1760,1,0$8;'(60$7e5,$8;&20%867,%/(6

TOP/ DESSUS 

0” 

RECESSED DEPTH / PROFONDEUR D'ENCASTRE 

20.5”

FLOOR / PLANCHER 

0” 

)5$0,1*127,1&/8',1*)$&(0$7(5,$/266$785(0$7e5,$8'()$d21121&2035,6

6,'(6&Ð7e6

³

%$&.$55,Ê5(

´

9(17723'(6686'8&21'8,7'¶e9(17

9(176,'(6 %27720&Ð7e6(7'(66286'8&21'8,7'e9(17

9(57,&$/9(17&21'8,7'¶e9(179(57,&$/

MANTEL / TABLETTE 

6" *

TOP, SIDES & BACK: PER STAND OFF SPACERS FOR FRAMING MATERIALS. FOR FINISHING MATERIALS
SEE OWNERS MANUAL

'(6686&27e6 $55,Ê5(6(/21/(6(63$&(856'('e*$*(0(173285/(60$7e5,$8;
'266$785(6(/21/$0$18(/'(35235,e7$,5(3285/(60$7e5,$8;'(),1,7,21

* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE INSTRUCTION 

0$18$/)25*5($7(5(;7(16,2165e)e5(5$80$18(/',16758&7,213285'(6

EXTENSIONS PLUS GRANDES.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR LES LONGUEURS 
D'EVACUATION MINIMALE ET MAXIMALE.

UN COMBUSTIBLE SOLIDE NE DOIT PAS ÊTRE UTILISÉ 
AVEC CET APPAREIL. UTILISER AVEC LES PORTES 
VITRÉES HOMOLOGUÉES SEULEMENT AVEC CETTE UNITÉ.

AVERTISSEMENT:

 

1¶$-287(=3$6$&(7$33$5(,/$8&810$7e5,$8'(9$17(175(5

EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR 
LE FABRICANT.  

THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT KITS. SEE 
OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND 

5(6($/,1*,61(&(66$5<$)7(56(59,&,1*7+(9(17$,5,17$.(6<67(0
/$33$5(,/'2,7e9$&8(56(6*$=(187,/,6$17/(16(0%/('e9$&8$7,2135235($
1$32/(215e)e5(5$80$18(/',167$//$7,21'(35235,e7$,5(3285/e9$&8$7,21
35e&,6(,/(67,03257$17'(%,(15e,167$//(5(75(6&(//(5/e9(17$35(6$92,5
$6685e/(0$,17,(1'86<67e0('(35,6('$,5

ELECTRICAL RATING: 115V, 60HZ. LESS THAN 12 AMPERES

63e&,),&$7,216e/(&75,48(69+=02,16'($03Ê5(

WOLF STEEL LTD.

24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA

SERIAL

180%(512'(6e5,(

LHD45

SAMPLE

E

*$6),5

*$6)

$=$9(&e9$&8

$=$9(&e9$&

81( 6$//( '( %$,1

1( 6$//( '( %$,

ON MOBILE SI SON INS

ON MOBILE SI SON 

6$=0+6e5,('(0$,6216

$=0+6e5,('(0$,6216

8 $8; e7$7681,6 '( /$ 1250(

e7$7681,6 '( /$ 1250

0$18)$&785e(67,75(&)56

785e(67,75(&)5

681,61(3(87Ç75($33/,48e(

7Ç75($33/,48e(

0(685(6 '( 6e&85,7e &2175(

(685(6 '( 6e&85,7e &2175(

$,6216 0$18)$&785e6 /(6 6,7(

$,6216 0$18)$&785e6 /(6 6,7

,167$//(5/¶$33$5(,/6(/21/(6

167$//(5/¶$33$5(,/6(/21/(

'(7(/65Ê*/(0(1766(/21

7(/65Ê*/(0(1766(/2

4001657 (NGZ) 

4001657 (NGZ) 

4001659 (WUSA)

4001659 (WUSA)

PP

ODEL 

ODEL 

CLHD4

CLHD

8'(e/e9$7,21

'(e/e9$7,21

UT / ALIMENTATION

UT / ALIMENTATION 

24

PL

SSURE/PRESSION AU COLLECTEUR

SURE/PRESSION AU C

ESSURE/PRESSION D'ALIMENTATIO

SSURE/PRESSION D'ALIME

RESSURE/PRESSION D'ALIMENTAT

ESSURE/PRESSION D'ALIMENT

LASS 

LASS 

/&20(

20(

IN CONTACT 

IN CONTACT 

:,7+7+($33/,$1&(

7+($33/,$1&(

D'ENCASTRE 20.5”

'ENCASTRE

$7e5,$8'()$d21121&2035,6

5,$8'()$d21121&2035,6

´

´

8,7'e9(17

OR FRAMING MATERIALS. FOR FINIS

OR FRAMING MATERIALS. FOR FIN

3$&(856'('e*$*(0(173285/(

(856'('e*$*(0(173285/

e7$,5(3285/(60$7e5,$8;'(

,5(3285/(60$7e5,$8;'(

SION HORIZONTALE MAXIMA

ON HORIZONTALE MAXI

5e)e5(5$80$18(/'

5e)e5(5$80$18(/

MINIMUM AND

MINIMUM AND

ROPRIETA

OPRIETA

UN COM

UN COM

AVEC

AVE

VIT

VIT

A

7.1A

THIS APPLIANCE USES A 4” EXHAUST / 7” AIR INTAKE VENT PIPE SYSTEM.

Refer to the section applicable to your installation. 

For safe and proper operation of the appliance follow the venting instruction exactly. Deviation from the 
minimum vertical vent length can create dif

fi

 culty in burner start-up and/or carboning. Under extreme vent 

con

fi

 gurations, allow several minutes (5-15) for the 

fl

 ame to stabilize after ignition. Provide a means for 

visually checking the vent connection to the appliance after the appliance is installed. Use a 

fi

 restop, vent pipe 

shield or attic insulation shield when penetrating interior walls, 

fl

 oor or ceiling.

NOTE: If for any reason the vent air intake system is disassembled; reinstall per the instructions 
provided for the initial installation.

!

WARNING

RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE.

IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3 FEET 

FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT 

NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM 

COMBUSTIBLES. USE WOLF STEEL LTD. SUPPORT RING ASSEMBLY W010-0370 OR EQUIVALENT 

NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARANCE TO COMBUSTIBLES 

FOR BOTH VERTICAL AND HORIZONTAL RUNS. SPACERS ARE ATTACHED TO THE INNER PIPE AT 

PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER PIPE. THIS GAP IS 

REQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED AT THE START, MIDDLE AND END OF 

EACH ELBOW TO ENSURE THIS GAP IS MAINTAINED. THESE SPACERS MUST NOT BE REMOVED. 

3.0 VENTING

Summary of Contents for CLHD45N

Page 1: ...your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualifi...

Page 2: ...NAL INSTALLATION 22 4 6 VERTICAL AIR TERMINAL INSTALLATION 22 4 7 USING FLEXIBLE VENTING 23 4 8 MOBILE HOME INSTALLATION 23 4 9 GAS INSTALLATION 24 5 0 FRAMING 25 5 1 MINIMUM CLEARANCE TO COMBUSTIBLE...

Page 3: ...IBLE ENCLOSURES section for drywall or other combustible material Framing see FRAMING section Side Wall Venting see VENTING section Framing see FRAMING section Enclosures see the section MINIMUM CLEAR...

Page 4: ...vented gas fired appliance Do not burn wood or other materials in the appliance It is imperative that the control compartments burners and circulating blower and its passageway in the appliance and v...

Page 5: ...5 W415 0895 C 03 13 12 2 1 DIMENSIONS 40 13 16 40 13 16 39 3 16 25 5 16 17 13 16 1 3 8 4 3 4 ELECTRICAL INLET ON LEFT SIDE GAS INLET 18 7 8 46 1 4 7 34 1 16 19 7 8 1 37 13 16 4 39 5 16 42 7 10 1 8...

Page 6: ...where the vent will pass through the house without cutting a floor or roof joist If the appliance is installed directly on carpeting vinyl tile or other combustible material other than wood flooring t...

Page 7: ...it is used Expansion contraction noises during heating up and cooling down cycles are normal and are to be expected NOTE The protective wrap on plated parts is best removed when the assembly is at roo...

Page 8: ...IL UTILISER AVEC LES PORTES VITR ES HOMOLOGU ES SEULEMENT AVEC CETTE UNIT AVERTISSEMENT 1 287 3 6 7 33 5 8 81 0 7e5 8 9 17 175 5 EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APP...

Page 9: ...rigid flexible components with the following termination kits wall terminal kit GD222 GD222R or 1 12 to 7 12 pitch roof terminal kit GD110 8 12 to 12 12 roof terminal kit GD111 flat roof terminal kit...

Page 10: ...IMUM 16 MINIMUM 37 13 16 8 MINIMUM 18 MAXIMUM FLEX VENT 24 MAXIMUM RIGID VENT 45 13 16 MINIMUM PLUS RISE 3 2 TYPICAL VENT INSTALLATIONS See VENTING section 37 13 16 NOTE There MUST be a 25 reduction i...

Page 11: ...air slot is located a minimum 12 above grade The maximum allowable vent length is 10 for a fireplace and 8 for a stove 9 1A 12 MIN TO GRADE 24 MINIMUM 3 3 1 PERISCOPE TERMINATION 3 3 2 CORNER TERMINA...

Page 12: ...jacent wall including neighbouring buildings P 8 8 Roof must be non combustible without openings Q 3 3 See chart for wider wall dimensions R 6 6 See chart for deeper wall dimensions The terminal shall...

Page 13: ...ontal run 3 times the vertical rise equal to or greater than the horizontal run 3 5 VENT APPLICATION FLOW CHART 14 1 For the following symbols used in the venting calculations and examples are greater...

Page 14: ...T HT VT 9 9 11 20 9 FT Formula 1 HT VT 9 9 11 Formula 2 HT VT 40 FT 20 9 40 Since both formulas are met this vent configuration is acceptable See graph to determine the required vertical rise VT for t...

Page 15: ...2 x 6 25 2 FT 10 7 25 2 Formula 2 HT VT 24 75 FT 16 7 24 75 Since both formulas are met this vent configuration is acceptable 0 5 15 20 100 50 150 12 5 8 57 147 2 The shaded area within the lines rep...

Page 16: ...xample V1 5 FT V2 6 FT V3 10 FT VT V1 V2 V3 5 6 10 21 FT H1 8 FT H2 2 5 FT HR H1 H2 8 2 5 10 5 FT HO 03 four 90 elbows 90 03 360 90 8 1 FT HT HR HO 10 5 8 1 18 6 FT HT VT 18 6 21 39 6 FT Formula 1 HT...

Page 17: ...1 4 5 20 6 FT Formula 1 HT 3VT 3VT 3 x 4 5 13 5 FT 16 1 13 5 Since this formula is not met this vent configuration is unacceptable Formula 2 HT VT 40 feet 20 6 40 Since only formula 2 is met this vent...

Page 18: ...ce NOTE A vent adaptor will be required directly off the appliance Follow vent manufacturer s installation instructions Different manufacturer s venting components must not be combined Once the prefer...

Page 19: ...NS RISK OF FIRE DO NOT ALLOW LOOSE MATERIALS OR INSULATION TO TOUCH THE VENT PIPE REMOVE INSULATION TO ALLOW FOR THE INSTALLATION OF THE ATTIC SHIELD AND TO MAINTAIN CLEARANCES TO COMBUSTIBLES 68 2A W...

Page 20: ...distributor See accessories to order specific kits required A Determine the air terminal location cut and frame a square opening as illustrated in the ceiling and the roof to provide the minimum 1 cl...

Page 21: ...position Measure the vent length required between terminal and appliance taking into account the additional length needed for the finished wall surface and any 1 overlaps between venting components B...

Page 22: ...enetrate the roof when fastened If the attic space is tight we recommend threading the Wolf Steel vent pipe collar or equivalent loosely onto the air terminal connector vent pipe assembly as it is pas...

Page 23: ...dealer distributor for the appropriate securing kit For mobile home installations the appliance must be fastened in place It is recommended that the appliance be secured in all installations Always t...

Page 24: ...on a soap and water solution Do not use open flame WARNING RISK OF FIRE EXPLOSION OR ASPHYXIATION ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES SUPPORT GAS CONTROL WHEN ATTACHING...

Page 25: ...Y CAUSE OVER HEATING AND FIRE PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION OR FRAMING AND OTHER COMBUSTIBLE MATERIALS BLOCK OPENING INTO THE CHASE TO PREVENT ENTRY OF BLOWN IN INSULATION MAKE SURE...

Page 26: ...0 8 41 DO NOT BUILD INTO THIS AREA IT MUST BE LEFT CLEAR TO PROVIDE ADEQUATE CLEARANCE FOR THE VENT IN THIS 14 WIDE AREA CENTERED ALONG THE FRONT OF THE FIREPLACE NO COMBUSTIBLES ARE ALLOWED FIREPLACE...

Page 27: ...imum of 1 all around the vent pipe on all vertical runs to combustibles is required except for clearances in appliance enclosures Vertical vent sections within enclosures require a minimum clearance o...

Page 28: ...ed that the enclosure be ventilated at the top and bottom to circulate the hot air 5 1 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES See VENTING section 56 MIN ENCLOSURE HEIGHT TOP OF FIREPLACE OPENING...

Page 29: ...29 W415 0895 C 03 13 12 Finishing material may be secured directly to the appliance body where practical COMBUSTIBLE NON COMBUSTIBLE TOP OF APPLIANCE OPENING 46 30 16 14 42 2...

Page 30: ...o combustibles are maintained Non combustible material can be used provided the minimum clearances to combustible materials are applied The minimum enclosure volume must be increased by no less than t...

Page 31: ...h A 25 5 16 B 6 2 C 8 4 D 10 6 E 12 8 E D C B A TOP OF APPLIANCE OPENING WARNING RISK OF FIRE MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY...

Page 32: ...r is secured to the top front edge of the firebox with two latches Pull the handles of the latches forward then lift the latches out from the door frame to release the top of the door Next pivot the d...

Page 33: ...33 W415 0895 C 03 13 12 2 1 6 2 LOGO PLACEMENT Place trim as shown into the slots of the right and left brackets behind the access panel LEFT BRACKET SHOWN 6 3 TRIM INSTALLATION...

Page 34: ...ag into your vacuum cleaner and vacuum out the glass media Replacement glass can be purchased from your local authorized dealer distributor CLEANING GLASS MEDIA Glass media may have a fine oil residue...

Page 35: ...E THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS WHEN INSTALLED ENSURE THAT ANY EXCESS WIRE IS CONTAINED PREVENTING IT FROM MAKING CONTACT WITH MOVING OR HOT OBJECTS 51 5 7 1 ACCES...

Page 36: ...AL section C Remove the fourteen screws from the valve train assembly Carefully lift the valve train assembly and turn off the manual shut off valve see GAS IN STALLATION section NOTE A new gasket may...

Page 37: ...r Ensure that the wires are routed safely away from hot objects and retained from the blower impellers Attach and secure the variable speed switch to the corner post However this is difficult to acces...

Page 38: ...TO THE ELECTRICAL CIRCUIT RISK OF ELECTRICAL SHOCK OR EXPLOSION DO NOT WIRE 110V TO THE VALVE OR TO THE APPLIANCE WALL SWITCH INCORRECT WIRING WILL DAMAGE CONTROLS ALL WIRING SHOULD BE DONE BY A QUAL...

Page 39: ...he appliance and remove the junction box assembly B Remove the one screw that secures the junction box to the junction box plate and slide off the clip C Route the supply wire through the 7 8 hole of...

Page 40: ...ND CONNECT TO OPTIONAL THERMOSTAT IPI BOARD DC SUPPLY TRANSFORMER VALVE ELECTRONIC This appliance comes equipped with a battery back up If this backup is used install 4 AA batteries not supplied into...

Page 41: ...WARNING IF YOU DO NOT FOLLOW THESE INSTRUC TIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE INITIAL LIGHTING OF THE PILOT AND MAIN BURNERS MUST BE...

Page 42: ...using screw B Gauge should read 3 5 water column for natural gas or 10 water column for propane Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWIS...

Page 43: ...ant to periodically perform a visual check of the pilot and burner flames Compare them to the illustration provided If any flames appear abnormal call a service person FLAME MUST ENVELOP UPPER 3 8 TO...

Page 44: ...of the ports which may not be burning or are not burning properly D Check to see that the pilot flame is large enough to engulf the flame sensor and or thermocouple thermopile as well as reaches the...

Page 45: ...ormal cleaning procedures given but require specialized techniques Contact you local authorized dealer distributor for complete cleaning instructions HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTI...

Page 46: ...a glass cleaner or vinegar and towel to clean If not cleaned properly before operating for the first time the marks can cause permanent blemishes on the plating After the plating is cured the fingerpr...

Page 47: ...D WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY WARNING 12 0 REPLACEMENTS COMPONENTS REF PART NO DESCRIPTION 1 W475 0680 CEMENT BOARD 2 W010 2222 BLACK DOOR FRAME 3 W010 2109 AS...

Page 48: ...RM MULTI COLOURED RIVER ROCKS 40 GA 72 HOT AIR EXHAUST KIT 41 GA 70 EXTENSION KIT 5FT 42 GA 566 HOT AIR DISTRIBUTION KIT 43 MKGK GLASS EMBERS BLACK 43 MKGB GLASS EMBERS BLUE 43 MKGR GLASS EMBERS RED 4...

Page 49: ...49 W415 0895 C 03 13 12 1 3 5 4 15 14 7 16 13 2 7 9 8 10 11...

Page 50: ...50 W415 0895 C 03 13 12 28 29 56 36 AT TE NT ION CH AU D CA UT ION HO T 32 31 30 42 41 40 57 37 21 22 23 27 25 26 24...

Page 51: ...into the module Check voltage of the transformer under load at the spade connections on the module with the ON OFF switch in the ON position Acceptable readings of a good transformer are between 6 2...

Page 52: ...me rectification Verify correct pilot orifice is installed and inlet gas specifications to manual Remember the flame carries the rectification current not the gas If the flame lifts from pilot hood th...

Page 53: ...r plate See RESTRICTING VENTS section if applicable Main burner flame is a blue lazy transparent flame Blockage in vent Remove blockage In really cold conditions ice buildup may occur on the terminal...

Page 54: ...ironmental conditions such as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pressures which m...

Page 55: ...55 W415 0895 C 03 13 12 15 0 SERVICE HISTORY 43 1...

Page 56: ...56 W415 0895 C 03 13 12...

Reviews: