We suggest that our woodburning hearth products 

be installed and serviced by professionals who are 

certified in the U.S. by the National Fireplace 

Institue® (NFI) as NFI Woodburning Specialists or 

who are certified in Canada by 

Wood Energy Technical 

Training (WETT).

with a layer of fi bre baffl es at the top to maintain a high temperature in the combustion chamber so that gases 
mixing with the preheated air from the secondary air manifold tube are easily ignited and burned. The appli-
ance sides and back are shielded to direct the heat upwards and forwards into the room.

Be sure to provide suffi cient combustion air. There are many other appliances in your home competing for air 
such as: a kitchen range hood, forced air heating devices or a bathroom exhaust fan. 

Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.

After extended periods of non-operation such as following a vacation or a warm weather season, the appliance 
may emit a slight odour for a few hours. This is caused by dust particles on the fi rebox burning off. Open a 
window to suffi ciently ventilate the room.

CALIFORNIA PROP 65 WARNING:

Use of this product may produce smoke which contains chemi-
cals known to the State of California to cause cancer, birth 
defects, or other reproductive harm.

If you experience smoking problems, you may need to open a 
door, a window or otherwise provide some method of supplying 
combustion air to the appliance.

HINT FOR INSTALLING PORCELAIN ENAMEL INSERTS:

Ensure the base of the porcelain side panels are protected from rubbing against the hearth when sliding your 
insert into the masonry fi replace.

Summary of Contents for CI-1402

Page 1: ...e admitted to the room or directly to the unit through a 4 diameter pipe This appliance is designed to burn natural wood only Higher efficiencies and lower emissions generally result when burning air...

Page 2: ...ISHING 13 5 1 BRICKS AND BAFFLES INSTALLATION 13 5 2 DOOR REMOVAL INSTALLATION 14 5 3 DOOR HANDLE INSTALLATION 14 5 4 FLASHING INSTALLATION 15 6 0 OPERATION 16 6 1 BLOWER 17 6 2 AIR CONTROL 18 6 3 FIR...

Page 3: ...1 0 INSTALLATION OVERVIEW Rating plate see RATING PLATE INFORMATION section Blower see BLOWER INSTALLATION section Door see DOOR AND HANDLE INSTALLATION section Flashing see FLASHING section Draft se...

Page 4: ...r servicing must be replaced prior to operating the appliance Under no circumstances should this appliance be modified This appliance must not be connected to a chimney flue pipe servicing a seperate...

Page 5: ...S APPLIANCE HAS NOT BEEN TESTED WITH ANY VENTED OR UNVENTED GAS LOG SET TO REDUCE RISK OF FIRE OR PREVENT INJURY DO NOT INSTALL A VENTED OR UNVENTED GAS LOG SET INTO THE APPLIANCE BURNING YOUR UNIT WI...

Page 6: ...exhaust products to easily flow through it Chimney vent systems that are too short or too long can also have an adverse affect on the flow of exhaust through it The wood burning appliance and chimney...

Page 7: ...rced air heating devices or a bathroom exhaust fan Expansion contraction noises during heating up and cooling down cycles are normal and to be expected After extended periods of non operation such as...

Page 8: ...E HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT 111KT A MINIMUM CLEARANCE OF 18 457mm TO THE CHIMNEY CONNECTOR MAY BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION RENSEIGNEZ VOUS AUPR S DESAUTORI...

Page 9: ...e more than 1 to the side of the insert or between the mantel and the top of the insert SIDEWALL COMBUSTIBLE MANTEL NON COMBUSTIBLE FACING A F G E C B D NON COMBUSTIBLE HEARTH AND THERMAL FLOOR PROTEC...

Page 10: ...E SMOKING OR AIR FLOW REVERSAL THE OUTSIDE AIR INLET MUST REMAIN CLEAR OF LEAVES DEBRIS ICE AND OR SNOW IT MUST BE UNRE STRICTED WHILE APPLIANCE IS IN USE TO PREVENT ROOM AIR STARVATION WHICH CAN CAUS...

Page 11: ...ver in position as high as possible with two masonry screws per side through the flanges into the fireplace In Canada Install a listed 6 inch diameter flexible stainless steel liner from the top of th...

Page 12: ...ements supersede any pre existing facing material clearances listed for the factory built fireplace C Installation must include a full height listed chimney liner meeting HT requirements 2100 F as re...

Page 13: ...nifold Ensure that the top baffles are pushed all the way to the rear of the firebox leaving a minimum of a 1 gap along the front This will allow the flue gases to escape the firebox C Install the bot...

Page 14: ...per rod below the door 5 3 DOOR HANDLE INSTALLATION BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE DO NOT STRIKE OR SLAM DOOR N...

Page 15: ...10 5 4 FLASHING INSTALLATION The top flashing has been shipped flat To install the flashing rest the bottom against the top of the appliance and secure using the tabs as illustrated below Slide the tr...

Page 16: ...rmally During the break in period the first 2 or 3 fires create only small hot fires using kindling this will allow the firebrick to cure Do not be alarmed if small hairline cracks develop in the fire...

Page 17: ...us and 450 degrees Fahrenheit 270 degrees Celsius A surface thermometer will help regulate this Without a appliance thermometer you are working blindly and have no idea of how the appliance is operat...

Page 18: ...e fully out Inadequate draft may cause back puffing into the room through the appliance and chimney connector points and may cause plugging of the chimney Too much draft may cause an excessive tempera...

Page 19: ...be ready for burning that fall Dry firewood has cracks in the end grain Cut the wood so that it will fit horizontally front to back making for easier loading and less of a likelihood that the wood wil...

Page 20: ...control on HIGH fully open for long periods of time one or two hours C Operating the appliance with the ash dump door blocked open or a poor gasket seal on the main door Has a direct flue connection...

Page 21: ...eaned at least once a year or as often as necessary Remove fibre baffles and clean above them once a year Replace any broken bricks WARNING TURN OFF THE POWER BEFORE SERVICING THE APPLIANCE APPLIANCE...

Page 22: ...t local authorities for further informa tion on how to handle a chimney fire After the chimney fire is out clean and inspect the chimney or chimney liner for stress and cracks prior to lighting anothe...

Page 23: ...EN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION DO NOT STRIKE SLAM OR SCRATCH GLASS DO NO...

Page 24: ...ng do not open the door until the fire is out and do not operate the appliance again until the glass has been replaced available from your Authorized dealer DO NOT SUBSTITUTE MATERIALS 5 3 HOT GLASS W...

Page 25: ...wo screws from the outer edge of the side panel s C Push the side panel toward the door and pull away from the insert releasing the panel from the keyed slot D Service or replace the blower s as requi...

Page 26: ...ILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY WARNING COMPONENTS RE...

Page 27: ...W BLACK DOOR EARLY AMERICAN 22 H222 GW GOLD DOOR EARLY AMERICAN 22 H222 SSW BRUSHED STAINLESS STEEL DOOR EARLY AMERICAN 23 CISK CAST IRON SURROUND KIT PAINTED BLACK 24 CISK A CAST IRON SURROUND KIT E...

Page 28: ...kage Inspect chimney Smokes when door is open Cold air blockage Burn a piece of paper to establish a draft Insufficient draft Add more pipe Let air stabilize before opening door Ensure baffles are pos...

Page 29: ...ust fans furnaces clothes dryers etc Any damages to appliance combustion chamber heat exchanger plated trim or other component due to water weather damage long periods of dampness condensation damagin...

Page 30: ...30 W415 0872 B 12 02 10 43 1 11 0 SERVICE HISTORY...