background image

8

W415-0872 / B / 12.02.10

2.5  RATING PLATE INFORMATION

1400

1400L

1402

LISTED SOLID FUEL BURNING FIREPLACE INSERT / 
ENCASTRÉ  À COMBUSTIBLE SOLIDE HOMOLOGUÉ

TESTED TO / TESTÉ SELON :

ULC S628 / UL 1482

FROM HEATER / DU POÊLE

RESIDENTIAL / RÉSIDENTIEL

1400

12IN/PO (305 mm)
12IN/PO (305 mm)

6IN/PO (150 mm)

USING DOUBLE  WALL CONNECTOR/UTILISATION

D’UN CONDUIT DE RACCORDEMENT À 

MAISON / MOBILE HOME*

1400

1400

10IN/PO (254 mm)

10IN/PO (254 mm)

6IN/PO (152 mm)

6IN/PO (152 mm)

4IN/PO (102 mm)

4IN/PO (102 mm)

EPI 1402

INSTALL AND USE ONLY IN 
ACCORDANCE WITH THE 
MANUFACTURER’S 
INSTRUCTIONS AND LOCAL 
BUILDING CODES. 
MINIMUM CEILING HEIGHT: 
7FT (2.13m)

HEARTH EXTENSION / 
COMBUSTIBLE FLOOR 
PROTECTION:

 IF INSTALLED 

ON A COMBUSTIBLE FLOOR, 
UNIT MUST BE PLACED ON A 
NON-COMBUSTIBLE FLOOR 
PROTECTOR EXTENDING 18” 
(455mm) IN FRONT AND 8” 
(205mm) TO THE SIDES AND 
BACK. 

CHIMNEY TYPE:

 MINIMUM 6” 

(152mm) DIAMETER 
APPROVED RESIDENTIAL 
TYPE FOR MOBILE HOME 
USE A CHIMNEY LISTED TO 
ULC S629 IN CANADA OR UL 
103HT IN THE USA.

CHIMNEY CONNECTOR:

 6” 

(152mm) DIAMETER MINIMUM 
24 GAUGE STEEL MINIMUM 
CLEARANCE FROM 
HORIZONTAL CONNECTOR 
AND CEILING 18” (455mm).
DO NOT OBSTRUCT SPACE 
UNDER HEATER.
SPECIAL METHODS ARE 
REQUIRED WHEN PASSING A 
CHIMNEY THROUGH A WALL 
OR CEILING. SEE INSTRUC-
TIONS AND BUILDING 
CODES.
DO NOT CONNECT THIS UNIT 
TO A CHIMNEY FLUE 
SERVING ANOTHER 
APPLIANCE.

FUEL:

 FOR USE WITH WOOD 

ONLY. DO NOT USE GRATE 
OR ELEVATE FIRE. BUILD 
WOOD FIRE DIRECTLY ON 
HEARTH.

WARNING:

 RISK OF SMOKE 

SPILLAGE. OPERATE ONLY 
WITH DOOR FULLY CLOSED.
REPLACE GLASS ONLY WITH 
CERAMIC GLASS.
DO NOT OVERFIRE. IF 
HEATER OR CHIMNEY 
CONNECTORS GLOW, YOU 
ARE OVERFIRING. INSPECT 
AND CLEAN CHIMNEY 
FREQUENTLY. UNDER 
CERTAIN CONDITIONS OF USE 
CREOSOTE BUILD-UP MAY 
OCCUR RAPIDLY.

OPTIONAL BLOWER KIT:

 

EP-62, 115V, 60HZ, 0.82AMP. 
ROUTE CORD AWAY FROM 
UNIT.

DANGER:

 RISK OF 

ELECTRICAL SHOCK. 
DISCONNECT POWER 
BEFORE SERVICING UNIT.

INSERT:

 INSTALL AND USE 

ONLY IN SOLID FUEL 
BURNING FIREPLACES. DO 
NOT REMOVE BRICKS OR 
MORTAR FROM SOLID FUEL 
BURNING FIREPLACE. 
INSTALL WITH A POSITIVE 
FLUE CONNECTOR AND 
FACEPLATE.

POUR INSTALLATION ET 
UTILISATION CONFORM

ÉMENT 

AUX INSTRUCTIONS DU 
FABRICANT ET AUX CODES 
LOCAUX DU BÂTIMENT.
HAUTEUR DE PLAFOND MINIMAL 
7PI (2,13m).

PROLONGEMENT 
D’ÂTRE/PROTECTION DU 
PLANCHER COMBUSTIBLE: 

SI 

INSTALLÉ SUR UN PLANCHER 
COMBUSTIBLE, L’APPAREIL DOIT 
ÊTRE PLACÉ SUR UNE PLAQUE 
PROTECTRICE INCOMBUSTIBLE 
S’ÉTENDANT SUR 18” (455mm) 

À 

L’AVANT ET 8” (205mm) À L’ARRIÈRE 
ET SUR LES CÔTÉS.

TYPE DE CHIMNÉE:

 DIAMÈTRE 

MINIMAL DE 6” (152mm) 
APPROUVÉE POUR USAGE 
RÉSIDENTIEL. MAISON MOBILE 
EMPLOYEZ UNE CHEMINÉE 
HOMOLOGUÉE ULC S629 AU 
CANADA OU UL 103HT AUX 
ÉTATS-UNIS.

RACCORD DE CHEMINÉE: 

DIAMÈTRE DE 6” (152mm) D’ACIER 
DE CALIBRE 24 MINIMUM. 18” 
(455mm) DE DÉGAGEMENT 
MINIMAL ENTRE LE RACCORD 
HORIZONTAL ET LE PLAFOND. 
NE RIEN ENTREPOSER SOUS 
L’APPAREIL.
DES MÉTHODES SPÉCIALES SONT 
REQUISES LORSQU’UNE 
CHEMINÉE TRAVERSE UN MUR OU 
UN PLAFOND. VOIR LES 
INSTRUCTIONS ET LES CODES DU 
BÂTIMENT. 
NE PAS RACCORDER À LA 
CHEMINÉE D’UN AUTRE APPAREIL.

COMBUSTIBLE:

 POUR USAGE 

AVEC LE BOIS SEULEMENT. 
N’UTILISEZ PAS DE CHENET OU NE 
SURÉLEVEZ PAS LE BOIS. 
PRÉPAREZ LE FEU DIRECTEMENT 
SUR L’ÂTRE.

AVERTISSEMENT: 

RISQUE 

D’ÉCHAPPEMENT DE FUMÉE. 
TENIR LA PORTE FERMÉE 
LORSQUE LE POÊLE FONCTIONNE. 
REMPLACEZ LA VITRE PAR UNE 
VITRE EN CÉRAMIQUE SEULEMENT. 
NE SURCHAUFFEZ PAS 
L’APPAREIL. SI L’APPAREIL OU LES 
RACCORDS ROUGEOIENT, 
L’APPAREIL SURCHAUFEE. 
INSPECTEZ ET NETTOYEZ LA 
CHEMINÉE FRÉQUEMMENT. DANS 
CERTAINES CONDITIONS, DES 
DÉPÔTS DE CRÉOSOTE PEUVENT 
SE FORMER RAPIDEMENT.

SOUFFLERIE OPTIONNELLE: 

EP-62, 115V, 60HZ, 0,82A. TENEZ LE 
CORDON ÉLECTRIQUE LOIN DE 
L’APPAREIL. 

DANGER:

 RISQUE DE SECOUSSE 

ÉLECTRIQUE. DÉBRANCHEZ AVANT 
DE PROCÉDER À L’ENTRETIEN.

ENCASTRÉ: 

INSTALLEZ ET UTILISEZ 

SEULEMENT DANS UN FOYER À 
COMBUSTIBLE SOLIDE. NE 
RETIREZ PAS DE MORTIER, NI 
BRIQUES DU FOYER À COMBUS-
TIBLE SOLIDE.
INSTALLEZ AVEC UNE GAINE 
CONFORME ET UNE PLAQUE DE 
RECOUVREMENT.

CONTACT LOCAL BUILDING FIRE OFFICIALS ABOUT RESTRICTIONS AND 
INSTALLATION INSPECTION IN YOUR AREA. MODEL 1400 IS SUITABLE FOR USE 
IN MOBILE HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT (111KT). A 
MINIMUM CLEARANCE OF 18” (457mm) TO THE CHIMNEY CONNECTOR MAY BE 
REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
RENSEIGNEZ-VOUS AUPR

ÈS DES AUTORITÉS LOCALES DU BÂTIMENT ET DU 

SERVICE DES INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONS 
D’INSTALLATION DANS VOTRE RÉGION. LES MODÈLES 1400 PEUVENT ÊTRE 
INSTALLÉS DANS UNE MAISON MOBILE SI INSTALLÉS CONJOINTEMENT AVEC UNE 
PRISE D’AIR EXTÉRIEUR (111KT). UN DÉGAGEMENT MINIMAL DE 18” (457mm) 
JUSQU’AU RACCORD DE LA CHEMINÉE PEUT ÊTRE EXIGÉ PAR L’AUTORITÉ AYANT 
JURIDICTION.

8"

8"

18"

8"

ALCOVE

A"

B"

C

BACK WALL (M/A)

45

°

SIDE W

A

LL

 (M/L)

BACK WALL (M/A)

SIDE W

A

LL

 (M/L)

B

A

IF THE STOVE IS TO BE INSTALLED ON A COMBUSTIBLE FLOOR, IT MUST BE 
PLACED ON AN APPROVED NON-COMBUSTIBLE HEARTH PAD, THAT 
EXTENDS 8” (200mm) BEYOND THE STOVE SIDES AND BACK, AND 18” 
(455mm) TO THE FRONT.
SI LE PO

ÊLE EST INSTALLÉ SUR UN PLANCHER COMBUSTIBLE, IL DOIT ÊTRE PLACÉ 

SUR UNE BASE DE PROTECTION INCOMBUSTIBLE CERTIFÉE QUI DOIT DÉPASSER 
LES CÔTÉS ET L’AMÉRE DU POÊLE DE 8” (200mm) ET SE PROLONGER DE 18” 
(455mm) SUR LE DEVANT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL WITH SINGLE WALL 
CHIMNEY CONNECTOR / D

ÉGAGEMENTS MINIMAUX AUX MATÉRIAUX 

COMBUSTIBLES AVEC RACCORD DE CHEMINÉE À PAROI SIMPLE:

*

MODEL 1400 MAY MAY BE INSTALLED INTO A MOBILE HOME IN THE UNITED 

STATES ONLY. 

*

LE MODÈLE 1400 NE PEUT ÊTRE INSTALLÉ QUE DANS UNE MAISON 

MOBILE AUX ÉTATS-UNIS SEULEMENT.

DOUBLE PAROI

CEILING / PLAFOND

C

D

B

A

FLOOR / PLANCHER

HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, 
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

QUAND L’APPAREIL FONCTIONNE, L A SURFACE DEVIENT 
CHAUDE. NE PAS TOUCHER. TENIR LES ENFANTS, LES 
VÊTEMENTS ET LES MEUBLES À L’ÉCAR

T

T. LE CONTACT PEUT 

CAUSER DES BRÛLURES À LA PEAU.

CAUTION:

ATTENTION:

U.S. ENVIRONMENTAL PROTECTION AGENCY 

Certifié conforme à la norme d’émanation de particules de juillet 1992.

W385-0401 / G

DATE CODE / DE DATE

EPA1400

 SKIN BURNS.

CLEARANCES TO COMBUSTIBLE CONSTRUCTION / 
D

ÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES: 

(MEASURED TO UNIT / À PARTIR DE L’APPAREIL)

A  SIDE FACING / CÔTÉ   

1 IN/PO (25mm)

*

B  TOP FACING / DESSUS 

28 IN/PO (710mm)

C  MANTEL / TABLETTE   

28 IN/PO (710mm)

D  SIDE WALL / MUR LATÉRAL 

17 IN/PO (430mm)

*

CLEARANCE TO EDGE OF FLASHING / DÉGAGEMENT AU 

BORD DE LA FAÇADE

LISTED SOLID FUEL BURNING SPACE HEATER / 

POÊLE À COMBUSTIBLE SOLIDE HOMOLOGUÉ 

MODEL / MODÈLE - EPA 1400

TESTED TO: / TESTÉ SELON : UL1482 / ULC S627 / CSA B366.2 (DEC 92)

1450

WOLF STEEL LTD.  

24 Napoleon Rd. Barrie, Ontario L4M 4Y8 Canada

WOLF STEEL USA

103 Miller Drive, Crittenden, Kentucky, USA, 41030

1400C

For rating plate location, see 
“INSTALLATION OVERVIEW” 
section.

This illustration is for refer-
ence only.  Refer to the rating 
plate on the appliance for 
accurate information.

SAMPLE

USING D

USING D

M

D

D

M

ON

ON 

OF SMOKE 

F SMOKE 

ERATE ONLY 

ATE ONLY 

FULLY CLOSED.

LY CLOSED.

SS ONLY WITH

ONLY WITH 

IF

U

US

CIALES SONT 

IALES SONT 

U’UNE

’UNE 

ERSE UN MUR OU

RSE UN MUR OU 

VOIR LES

LES 

ONS ET LES CODES DU

S CODES DU

T.

T. 

S RACCORDER 

RACCORD

À LA 

À

EMIN

MIN

ÉE D’UN AUTRE APPAREIL.

ÉE D’UN AUTRE APPAREIL.

OMBUSTIBLE:

BUSTIBLE:

 POUR USAGE

 POUR USAGE

A

AVEC LE BOIS SEULEMENT.

LE BOIS SEULEMENT. 

N’UTILISEZ PAS DE CHENET OU N

SEZ PAS DE CHENET OU N

SURÉLEVEZ PAS LE BOIS.

VEZ PAS LE BOIS. 

PRÉPAREZ LE FEU DIRECTE

PRÉPAREZ LE FEU DIR

SUR L’

S

ÂTRE.

E.

AVERTISSEMENT:

AVERTISSEMENT: 

RISQ

RIS

SA

D’

D’

ÉCHAPPEMENT DE

ÉCHAPPEMENT DE

TENIR LA PORTE F

TENIR LA PORTE 

LORSQUE LE P

LORSQUE L

REMPLACEZ

MPLACE

VITRE EN C

VITRE EN 

NE SUR

NE SUR

L’AP

L’AP

RA

S

NT MIN

NT MIN

ÊTRE EXIGÉ

TRE EXIG

LEEEE

ALCOVE

ALCOVE

A"

A"

B"

B"

EEEEEEE

LEE

LE

LLLE

LE

LE

LL

C

S

IDE W

A

LL

 (

M/L

)

W

A

LL

 (M/L)

MPLE

O BE INSTALLED ON A COMBUSTIBL

O BE INSTALLED ON A COMBUSTIBL

APPROVED NON-COMBUSTIBLE HEA

PROVED NON-COMBUSTIBLE HE

200mm) BEYOND THE STOVE SIDES

BEYOND THE STOVE SIDE

O THE FRONT.

THE FRONT.

LE EST INSTALL

LE EST INSTA

É SUR UN PLANCHER 

SUR UN PLANCHER

NE BASE DE PROTECTION INCOMBUSTIB

E BASE DE PROTECTION INCOMBUSTI

CÔTÉS ET L’AM

CÔTÉS ET L’AM

ÉRE DU 

ÉRE D

PO

ÊLE DE 8” (2

E DE 8” (2

455mm) SUR LE DEVANT.

55mm) SUR LE DEVANT

MINIMUM CLEARANCE TO COMBUS

NIMUM CLEARANCE

P

CHIMNEY CONNECTOR / 

CHIMNEY CONNECT

D

ÉGAG

PP

COMBUSTIBLES

COMBUSTIBLES

AVEC RACCOR

 AVEC

MP

Summary of Contents for CI-1402

Page 1: ...e admitted to the room or directly to the unit through a 4 diameter pipe This appliance is designed to burn natural wood only Higher efficiencies and lower emissions generally result when burning air...

Page 2: ...ISHING 13 5 1 BRICKS AND BAFFLES INSTALLATION 13 5 2 DOOR REMOVAL INSTALLATION 14 5 3 DOOR HANDLE INSTALLATION 14 5 4 FLASHING INSTALLATION 15 6 0 OPERATION 16 6 1 BLOWER 17 6 2 AIR CONTROL 18 6 3 FIR...

Page 3: ...1 0 INSTALLATION OVERVIEW Rating plate see RATING PLATE INFORMATION section Blower see BLOWER INSTALLATION section Door see DOOR AND HANDLE INSTALLATION section Flashing see FLASHING section Draft se...

Page 4: ...r servicing must be replaced prior to operating the appliance Under no circumstances should this appliance be modified This appliance must not be connected to a chimney flue pipe servicing a seperate...

Page 5: ...S APPLIANCE HAS NOT BEEN TESTED WITH ANY VENTED OR UNVENTED GAS LOG SET TO REDUCE RISK OF FIRE OR PREVENT INJURY DO NOT INSTALL A VENTED OR UNVENTED GAS LOG SET INTO THE APPLIANCE BURNING YOUR UNIT WI...

Page 6: ...exhaust products to easily flow through it Chimney vent systems that are too short or too long can also have an adverse affect on the flow of exhaust through it The wood burning appliance and chimney...

Page 7: ...rced air heating devices or a bathroom exhaust fan Expansion contraction noises during heating up and cooling down cycles are normal and to be expected After extended periods of non operation such as...

Page 8: ...E HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT 111KT A MINIMUM CLEARANCE OF 18 457mm TO THE CHIMNEY CONNECTOR MAY BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION RENSEIGNEZ VOUS AUPR S DESAUTORI...

Page 9: ...e more than 1 to the side of the insert or between the mantel and the top of the insert SIDEWALL COMBUSTIBLE MANTEL NON COMBUSTIBLE FACING A F G E C B D NON COMBUSTIBLE HEARTH AND THERMAL FLOOR PROTEC...

Page 10: ...E SMOKING OR AIR FLOW REVERSAL THE OUTSIDE AIR INLET MUST REMAIN CLEAR OF LEAVES DEBRIS ICE AND OR SNOW IT MUST BE UNRE STRICTED WHILE APPLIANCE IS IN USE TO PREVENT ROOM AIR STARVATION WHICH CAN CAUS...

Page 11: ...ver in position as high as possible with two masonry screws per side through the flanges into the fireplace In Canada Install a listed 6 inch diameter flexible stainless steel liner from the top of th...

Page 12: ...ements supersede any pre existing facing material clearances listed for the factory built fireplace C Installation must include a full height listed chimney liner meeting HT requirements 2100 F as re...

Page 13: ...nifold Ensure that the top baffles are pushed all the way to the rear of the firebox leaving a minimum of a 1 gap along the front This will allow the flue gases to escape the firebox C Install the bot...

Page 14: ...per rod below the door 5 3 DOOR HANDLE INSTALLATION BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE DO NOT STRIKE OR SLAM DOOR N...

Page 15: ...10 5 4 FLASHING INSTALLATION The top flashing has been shipped flat To install the flashing rest the bottom against the top of the appliance and secure using the tabs as illustrated below Slide the tr...

Page 16: ...rmally During the break in period the first 2 or 3 fires create only small hot fires using kindling this will allow the firebrick to cure Do not be alarmed if small hairline cracks develop in the fire...

Page 17: ...us and 450 degrees Fahrenheit 270 degrees Celsius A surface thermometer will help regulate this Without a appliance thermometer you are working blindly and have no idea of how the appliance is operat...

Page 18: ...e fully out Inadequate draft may cause back puffing into the room through the appliance and chimney connector points and may cause plugging of the chimney Too much draft may cause an excessive tempera...

Page 19: ...be ready for burning that fall Dry firewood has cracks in the end grain Cut the wood so that it will fit horizontally front to back making for easier loading and less of a likelihood that the wood wil...

Page 20: ...control on HIGH fully open for long periods of time one or two hours C Operating the appliance with the ash dump door blocked open or a poor gasket seal on the main door Has a direct flue connection...

Page 21: ...eaned at least once a year or as often as necessary Remove fibre baffles and clean above them once a year Replace any broken bricks WARNING TURN OFF THE POWER BEFORE SERVICING THE APPLIANCE APPLIANCE...

Page 22: ...t local authorities for further informa tion on how to handle a chimney fire After the chimney fire is out clean and inspect the chimney or chimney liner for stress and cracks prior to lighting anothe...

Page 23: ...EN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION DO NOT STRIKE SLAM OR SCRATCH GLASS DO NO...

Page 24: ...ng do not open the door until the fire is out and do not operate the appliance again until the glass has been replaced available from your Authorized dealer DO NOT SUBSTITUTE MATERIALS 5 3 HOT GLASS W...

Page 25: ...wo screws from the outer edge of the side panel s C Push the side panel toward the door and pull away from the insert releasing the panel from the keyed slot D Service or replace the blower s as requi...

Page 26: ...ILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY WARNING COMPONENTS RE...

Page 27: ...W BLACK DOOR EARLY AMERICAN 22 H222 GW GOLD DOOR EARLY AMERICAN 22 H222 SSW BRUSHED STAINLESS STEEL DOOR EARLY AMERICAN 23 CISK CAST IRON SURROUND KIT PAINTED BLACK 24 CISK A CAST IRON SURROUND KIT E...

Page 28: ...kage Inspect chimney Smokes when door is open Cold air blockage Burn a piece of paper to establish a draft Insufficient draft Add more pipe Let air stabilize before opening door Ensure baffles are pos...

Page 29: ...ust fans furnaces clothes dryers etc Any damages to appliance combustion chamber heat exchanger plated trim or other component due to water weather damage long periods of dampness condensation damagin...

Page 30: ...30 W415 0872 B 12 02 10 43 1 11 0 SERVICE HISTORY...

Page 31: ...31 W415 0872 B 12 02 10 44 1 12 0 NOTES...

Page 32: ...32 W415 0872 B 12 02 10 44 1...

Reviews: