27
W415-0889 / A / 08.11.10
5.2 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES
For temperature requirements, the enclosure space around and above the appliance must be left unobstructed.
It is recommended that the enclosure be ventilated at the top and bottom to circulate the hot air.
* See “VENTING” section.
84”
46”
38”
9 1/2”
NON-
COMBUSTIBLE
MATERIAL
2”
1”
WOOD
HEADER
62”
MINIMUM
PLUS
RISE*
FRONT HOOD
1”
COMBUSTIBLE
NON-COMBUSTIBLE
BRICK
0” IF NON-COMBUSTIBLE
FINISHING IS USED SUCH
AS BRICK AND STONE
18”
1 1/4”