4.7 NATURAL VENT SPECIFICS
4.7.1 CHIMNEY INSTALLATION
63.7B
“A” VENT - SOLID
FUEL WOOD BURNING
CHIMNEY & VENT
CONNECTOR
(LINER NEEDED
IF INSIDE
DIAMETER IS 6”
(152mm) OR
LARGER)
SINGLE WALL
OR “B” VENT
MASONRY CLAY LINED
C VENT
CONNECTOR
[NO NEW LINER
NEEDED IF OLD
LINER DIAMETER IS
4-5” (102-127mm)]
SINGLE WALL
OR “B” VENT
“B” VENT
GAS BURNING
CHIMNEY
A CHIMNEY VENTING THIS APPLIANCE SHALL NOT VENT ANY SOLID FUEL BURNING APPLIANCE.
!
WARNING
A chimney venting this appliance shall not vent any solid fuel burning appliance.
All horizontal runs must have a 1/4" (6.4mm) rise per foot (0.3m).
Three types of chimney systems may be used with this appliance.