background image

3

W415-0149 / B / 11.25.09

CONTINENTAL gas fireplaces are manufactured under the strict Standard of the world recognized

ISO9002 Quality Assurance Certificate.

CONTINENTAL products are designed with superior components and materials, assembled by trained craftsmen
who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station.
Once assembled the complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure
that you, the customer, receives the quality product that you expect from WOLF STEEL Ltd..

CONTINENTAL GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY

The following materials and workmanship in your new 

The following materials and workmanship in your new 

The following materials and workmanship in your new 

The following materials and workmanship in your new 

The following materials and workmanship in your new CONTINENTAL

CONTINENTAL

CONTINENTAL

CONTINENTAL

CONTINENTAL gas fireplace are

 gas fireplace are

 gas fireplace are

 gas fireplace are

 gas fireplace are

warranted against defects for as long as you own the fireplace. This covers: combustion chamber,

warranted against defects for as long as you own the fireplace. This covers: combustion chamber,

warranted against defects for as long as you own the fireplace. This covers: combustion chamber,

warranted against defects for as long as you own the fireplace. This covers: combustion chamber,

warranted against defects for as long as you own the fireplace. This covers: combustion chamber,
heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage

heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage

heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage

heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage

heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage
only), gold plated parts against tarnishing, porcelainized enamelled components and aluminium

only), gold plated parts against tarnishing, porcelainized enamelled components and aluminium

only), gold plated parts against tarnishing, porcelainized enamelled components and aluminium

only), gold plated parts against tarnishing, porcelainized enamelled components and aluminium

only), gold plated parts against tarnishing, porcelainized enamelled components and aluminium
extrusion trims.

extrusion trims.

extrusion trims.

extrusion trims.

extrusion trims.

Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,

Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,

Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,

Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,

Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,

thermal switch, switches, wiring, remote controls, igniter, gasketing, and pilot assembly are

thermal switch, switches, wiring, remote controls, igniter, gasketing, and pilot assembly are

thermal switch, switches, wiring, remote controls, igniter, gasketing, and pilot assembly are

thermal switch, switches, wiring, remote controls, igniter, gasketing, and pilot assembly are

thermal switch, switches, wiring, remote controls, igniter, gasketing, and pilot assembly are
covered and 

covered and 

covered and 

covered and 

covered and WOLF STEEL 

WOLF STEEL 

WOLF STEEL 

WOLF STEEL 

WOLF STEEL LTD. 

LTD. 

LTD. 

LTD. 

LTD.  will provide replacement parts free of charge during the first

will provide replacement parts free of charge during the first

will provide replacement parts free of charge during the first

will provide replacement parts free of charge during the first

will provide replacement parts free of charge during the first

year of the limited warranty.

year of the limited warranty.

year of the limited warranty.

year of the limited warranty.

year of the limited warranty.

Any labour related to warranty repair is not covered.

Any labour related to warranty repair is not covered.

Any labour related to warranty repair is not covered.

Any labour related to warranty repair is not covered.

Any labour related to warranty repair is not covered.

CONDITIONS AND LIMITATIONS

WOLF STEEL LTD. warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears on

the warranty registration card filed with WOLF STEEL Ltd. -- provided that the purchase was made through an authorized CONTINENTAL dealer and is subject to the following conditions
and limitations:

This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.

The gas fireplace must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the

product and all local and national building and fire codes.

This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this

warranty.

This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel

parts, mechanical breakage of PHAZER™ logs and embers, nor any venting components used in the installation of the fireplace.

WOLF STEEL Ltd. warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During the first 10 years WOLF STEEL Ltd.

will replace or repair the defective parts at our option free of charge. From 10 years to life, WOLF STEEL LTD. will provide replacement burners at 50% of the current retail price.

In the first year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in

accordance with the operation instructions and under normal conditions.

After the first year, with respect to this President's Limited Lifetime Warranty, WOLF STEEL LTD. may, at its discretion, fully discharge all obligations with respect to this warranty by refunding

to the original warranted purchaser the wholesale price of any warranted but defective part(s).

WOLF STEEL Ltd. will not be responsible for installation, labour, or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not covered by this

warranty.

Notwithstanding any provisions contained in this President's Limited Lifetime Warranty, WOLF STEEL’S responsibility under this warranty is defined as above and it shall not in any event

extend to any incidental, consequential or indirect damages.

This warranty defines the obligations and liability of WOLF STEEL Ltd. with respect to the CONTINENTAL gas fireplace and any other warranties expressed or implied with respect to this

product, its components or accessories are excluded.

WOLF STEEL Ltd. neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. WOLF STEEL Ltd. will not be responsible

for: over-firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting
configurations, insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.

Any damages to fireplace, combustion chamber, heat exchanger, brass trim or other component  due to water, weather damage, long periods of dampness, condensation, damaging chemicals

or cleaners will not be the responsibility of WOLF STEEL Ltd.

The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration card

must be returned within fourteen days to register the warranty.

WOLF STEEL Ltd. reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.

ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED
TRADEMARK OF WOLF STEEL LTD.  PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD.

Summary of Contents for CDVS 280-N

Page 1: ...ada L4M 4Y8 705 721 1212 Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in these instructions is not followed exactly...

Page 2: ...or clothing ignition Supervise young children when they are in the same room as the stove Due to high temperatures the stove should be located out of traffic and away from furniture and draperies Clot...

Page 3: ...ty repair is not covered Any labour related to warranty repair is not covered Any labour related to warranty repair is not covered CONDITIONS AND LIMITATIONS WOLF STEEL LTD warrants its products again...

Page 4: ...gas and 13 inches water column for propane When the valve is set to HI the manifold pres sure under flow conditions is 3 5 inches water column for natural gas and 10 inches water column for propane W...

Page 5: ...ing LOCATIONANDCLEARANCES Provide adequate ventilation and combustion air Provide adequate accessibility clearance for servicing and operating the stove Never obstruct the front opening of the stove C...

Page 6: ...combined OFFSET INSTALLATION EXAMPLE If a first run of 72 inches is re quired using the First Vent Run on the chart shows that a maxi mum second run of 48 inches is allowable IF NECESSARY THE FIRST R...

Page 7: ...Clearance above grade veranda porch deck or balcony Clearance to windows or doors that open Clearance to permanently closed windows Vertical clearance to ventilated soffit located above the terminal w...

Page 8: ...lled in its final position apply sealant between the pipe and the firestop spacer 3 In the attic after the pipe has been installed slide the vent pipe collar down to cover up the open end of the shiel...

Page 9: ...ts onto the air terminal Tighten securely 6 Attach the vertical rain cap 7 In the attic slide the vent pipe collar down to cover up the open end of the shield and tighten This will prevent any materia...

Page 10: ...f the base For mobile home installations the fireplace must be fastened in place Use 10 screws inserted through the holes in the base to se cure It is recommended that the fireplace be secured in all...

Page 11: ...n with the screw supplied 7 Unscrew the wire access cover plate from the rear right hand side of the firebox Remove and discard the gasket Remove the knockout from the cover plate and insert the prote...

Page 12: ...roof or building within 10 feet This is a guideline only local venting codes should be followed which may differ in height and clearance require ments Continue with Gas Installation Page 13 INSTALLING...

Page 13: ...PPLIQUENT SEULEMENTAU CANADA AFUE NG LP GN GP 64 65 MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20 FEET RESPECTIVELY LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES ET...

Page 14: ...t to ensure that it is in a horizontal position To open the door repeat in reverse order Place the front log on the ember screen lining up the studs with the holes on the bottom of the log HINGE PIN B...

Page 15: ...Allow several minutes 5 15 for the flame to stabilize after ignition MODEL CS280 ONLY SPILL SWITCH This is a thermally activated switch attached to the back of the chimney adapter which senses the cha...

Page 16: ...VICING THE APPLIANCE CAUTION Label all wires prior to disconnection when serv icing controls Wiring errors can cause improper and dan gerous operation Verify proper operation after servicing This stov...

Page 17: ...at the wires are neither pinched nor interfere with the blower operation Resecure the air intake manifolds INSTALLATION THROUGH THE FIRE BOX Replacement blower access gasket is required 2 Open the low...

Page 18: ...curing the control panel plate To access the venturi remove the 2 screws securing the air housing cover plate Take care not to damage the gasket Natural gas and propane models have air shutters set fu...

Page 19: ...RE BRTC7 BRASS TRIM COLLAR BM6724 24 STOVE PIPE 7 DIAMETER W10 0300 10 ALUMINUM FLEX LINER C W SPACERS 4 DIA W25 0001 DECORATIVE BRASS BAND GD180 PERISCOPE TERMINAL KIT BM6790 90 ELBOW 7 DIAMETER GD20...

Page 20: ...660 009 ON OFF SWITCH W690 0002 THERMODISC W380 0002 VARIABLE SPEED SWITCH KNOB KB 13 VARIABLE SPEED SWITCH GZ 552 REPLACEMENT BLOWER CS280 W010 0459 ADAPTER C W SPILL SWITCH W660 0006 SPILL SWITCH AC...

Page 21: ...s to code Correct all undersized piping MODEL CS280 ONLY Venting is spilling test with spill switch bypassed Replace if defective check for vent blockage Pilot flame is not large enough turn up the pi...

Page 22: ...rrect location of storm collars Incorrect installation Carbon is being de posited on glass logs or combustion chamber surfaces Flame is impinging on the logs or combustion chamber check that the logs...

Page 23: ...W415 0149 B 11 25 09 Wolf Steel Fireplace Service History This fireplace must be serviced at least annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Na...

Page 24: ...24 W415 0149 B 11 25 09 NOTES...