The on-off switch is located on the back of the unit at the top left corner on models CDVS280 and CS280.

When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused
by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not
occur again. Simply open a window to sufficiently ventilate the room. After extended periods of non-operation such as
following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by
dust particles in the heat exchanger burning off. Open a window to sufficiently ventilate the room.

MODEL CS280 ONLY:

VENTING AC-

TION CHECK

A check for correct venting action must be made
before the installed stove is left with the customer.
Test  in the following manner:

1.  Close all doors and windows in the room / start

exhaust fans in the home / turn fire-
place blower off (if equipped).

2.  Set controls to "high" and light

the unit.

3.  Wait 5 minutes. Light a match

and extend it 1" into the hole located
above the spill switch bracket on the
adapter.

4.  Venting action is satisfactory if

the flame stays lit. Venting action is
unsatisfactory if the flame extin-
guishes.

5.   If venting action is unsatisfactory, turn the unit off,

wait 10 minutes and try again. If the match does not stay
lit, turn the unit off and check for vent blockage or restric-
tion. If necessary, consult with a qualified inspector.

Purge all gas lines with the glass door open. Assure that
a continuous gas flow is at the burner before closing the
door. Allow several minutes (5-15) for the flame to stabilize
after ignition.

MODEL CS280 ONLY:

 

SPILL

SWITCH

This is a thermally activated switch, attached to the back
of the chimney adapter, which senses the change in
temperature and shuts down the gas valve in the event
of a severe downdraft of air or a blocked or disconnected
vent. It acts as a safety shut-off to prevent a build up of

carbon monoxide or an explosion of unburnt gases during
start up. If the flue is blocked or has no "draw", the spill
switch will automatically shut off the supply of gas within
about 5-10 minutes.

TAMPERING WITH THE SWITCH CAN RESULT IN CAR-
BON MONOXIDE (CO) POISONING AND POSSIBLE
DEATH.

OPERATION / MAINTENANCE

WARNING: 

If you do not follow these instructions

exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
A. This fireplace is equipped with a pilot which must be lit

by hand while following these instructions exactly.

B.  Before operating smell all around the fireplace area

for gas and next to the floor because some gas is
heavier than air and will settle on the floor.

C. Use only your hand to turn the gas control knob / manual

shut-off knob. never use tools. If the knob will not turn by
hand, do not try to repair it. Call a qualified service tech-
nician. force or attempted repair may result in a fire or
explosion.

D. Do not use this fireplace if any part has been under

water. Immediately call a qualified service technician to
inspect the fireplace and replace any part of the control
system and any gas control which has been under water.

WHAT TO DO IF YOU SMELL GAS:

• Turn off all gas to the fireplace.
• Open windows.
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone

in your building.

• Immediately call your gas supplier from a neighbour's

phone. follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire de-

partment.

Summary of Contents for CDVS 280-N

Page 1: ...ada L4M 4Y8 705 721 1212 Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in these instructions is not followed exactly...

Page 2: ...or clothing ignition Supervise young children when they are in the same room as the stove Due to high temperatures the stove should be located out of traffic and away from furniture and draperies Clot...

Page 3: ...ty repair is not covered Any labour related to warranty repair is not covered Any labour related to warranty repair is not covered CONDITIONS AND LIMITATIONS WOLF STEEL LTD warrants its products again...

Page 4: ...gas and 13 inches water column for propane When the valve is set to HI the manifold pres sure under flow conditions is 3 5 inches water column for natural gas and 10 inches water column for propane W...

Page 5: ...ing LOCATIONANDCLEARANCES Provide adequate ventilation and combustion air Provide adequate accessibility clearance for servicing and operating the stove Never obstruct the front opening of the stove C...

Page 6: ...combined OFFSET INSTALLATION EXAMPLE If a first run of 72 inches is re quired using the First Vent Run on the chart shows that a maxi mum second run of 48 inches is allowable IF NECESSARY THE FIRST R...

Page 7: ...Clearance above grade veranda porch deck or balcony Clearance to windows or doors that open Clearance to permanently closed windows Vertical clearance to ventilated soffit located above the terminal w...

Page 8: ...lled in its final position apply sealant between the pipe and the firestop spacer 3 In the attic after the pipe has been installed slide the vent pipe collar down to cover up the open end of the shiel...

Page 9: ...ts onto the air terminal Tighten securely 6 Attach the vertical rain cap 7 In the attic slide the vent pipe collar down to cover up the open end of the shield and tighten This will prevent any materia...

Page 10: ...f the base For mobile home installations the fireplace must be fastened in place Use 10 screws inserted through the holes in the base to se cure It is recommended that the fireplace be secured in all...

Page 11: ...n with the screw supplied 7 Unscrew the wire access cover plate from the rear right hand side of the firebox Remove and discard the gasket Remove the knockout from the cover plate and insert the prote...

Page 12: ...roof or building within 10 feet This is a guideline only local venting codes should be followed which may differ in height and clearance require ments Continue with Gas Installation Page 13 INSTALLING...

Page 13: ...PPLIQUENT SEULEMENTAU CANADA AFUE NG LP GN GP 64 65 MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20 FEET RESPECTIVELY LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES ET...

Page 14: ...t to ensure that it is in a horizontal position To open the door repeat in reverse order Place the front log on the ember screen lining up the studs with the holes on the bottom of the log HINGE PIN B...

Page 15: ...Allow several minutes 5 15 for the flame to stabilize after ignition MODEL CS280 ONLY SPILL SWITCH This is a thermally activated switch attached to the back of the chimney adapter which senses the cha...

Page 16: ...VICING THE APPLIANCE CAUTION Label all wires prior to disconnection when serv icing controls Wiring errors can cause improper and dan gerous operation Verify proper operation after servicing This stov...

Page 17: ...at the wires are neither pinched nor interfere with the blower operation Resecure the air intake manifolds INSTALLATION THROUGH THE FIRE BOX Replacement blower access gasket is required 2 Open the low...

Page 18: ...curing the control panel plate To access the venturi remove the 2 screws securing the air housing cover plate Take care not to damage the gasket Natural gas and propane models have air shutters set fu...

Page 19: ...RE BRTC7 BRASS TRIM COLLAR BM6724 24 STOVE PIPE 7 DIAMETER W10 0300 10 ALUMINUM FLEX LINER C W SPACERS 4 DIA W25 0001 DECORATIVE BRASS BAND GD180 PERISCOPE TERMINAL KIT BM6790 90 ELBOW 7 DIAMETER GD20...

Page 20: ...660 009 ON OFF SWITCH W690 0002 THERMODISC W380 0002 VARIABLE SPEED SWITCH KNOB KB 13 VARIABLE SPEED SWITCH GZ 552 REPLACEMENT BLOWER CS280 W010 0459 ADAPTER C W SPILL SWITCH W660 0006 SPILL SWITCH AC...

Page 21: ...s to code Correct all undersized piping MODEL CS280 ONLY Venting is spilling test with spill switch bypassed Replace if defective check for vent blockage Pilot flame is not large enough turn up the pi...

Page 22: ...rrect location of storm collars Incorrect installation Carbon is being de posited on glass logs or combustion chamber surfaces Flame is impinging on the logs or combustion chamber check that the logs...

Page 23: ...W415 0149 B 11 25 09 Wolf Steel Fireplace Service History This fireplace must be serviced at least annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Na...

Page 24: ...24 W415 0149 B 11 25 09 NOTES...

Reviews: