W415-1283 / E / 12.21.16
17
Simple venting configuration (only one 45° and 90°
elbow)
See graph to determine the required vertical
rise
V
T
for the required horizontal run
H
T
.
150 (3810)
147 (3733.8)
REQUIRED
VERTICAL RISE
IN INCHES
(MILLIMETERS)
V
T
100 (2540)
57 (1447.8)
50 (1270)
0
5
10
15
20
(1.5)
(3.1) 12.5 (4.6)
(3.8)
(6.1)
HORIZONTAL VENT RUN PLUS
OFFSET IN FEET (METERS)
H
T
The shaded area within the lines represents acceptable values for
H
T
and
V
T
For vent configurations requiring more than one 45° elbow and 90° elbow, the following formulas
apply:
Formula 1: H
T
< 4.2 V
T
Formula 2: H
T
+ V
T
< 24.75 feet (7.5m)
Example:
90°
90°
90 °
H
H
4
3
V
H
1
H
2
V
1
= 4 FT (1.2m)
2
90°
V
2
= 1.5 FT (0.5m)
V
V
T
=
V
1
+
V
2
= 4 FT (1.2m) + 1.5 FT (0.5m) = 5.5 FT (1.7m)
H
1
= 2 FT (0.6m)
H
2
= 1 FT (0.3m)
H
3
= 1 FT (0.3m)
H
4
= 1.5 FT (0.5m)
45°
H
R
=
H
1
+
H
2
+
H
3
+
H
4
= 2FT (0.6m) + 1FT (0.3m) + 1FT (0.3m) + 1.5FT (0.5m) = 5.5 FT (1.7m)
H
O
= .03 (one 45° elbow + four 90° elbows - 135°) = .03 (405 - 135°) = 8.1 FT (2.5m)
H
T
=
H
R
+
H
O
= 5.5 FT (1.7m) + 8.1 FT (2.5m) = 13.6 FT (4.2m)
H
T
+
V
T
= 13.6 FT (4.2m) + 5.5 FT (1.7m) = 19.1 FT (5.8m)
Formula 1:
H
T
< 4.2FT (1.3m) V
T
4.2FT (1.3m) V
T
= 4.2 FT (1.3m) x 5.5 FT (1.7m)= 23.1 FT (7m)
13.6 FT (4.2m) < 23.1 FT (7M)
Formula 2:
H
T
+ V
T
< 24.75 FT (7.5m)
19.1 FT (5.8m) < 24.75 FT (7.5m)
Since both formulas are met, this vent configuration is acceptable.
16.5_2A