33
W415-0780 / D / 08.13.12
7.0 OPTIONAL BLOWER INSTALLATION
7.1 ACCESSING THE BLOWER
A.
Remove the main door, see "DOOR
INSTALLATION / REMOVAL" section.
B.
Carefully remove the logs.
C.
Remove the grate by lifting it off of the two
securing pins.
D.
Remove the 6 screws as illustrated and lift
out the log support. Be careful not to lose the
spacers for the screws indicated.
E.
Remove the 7 perimeter screws as illustrated
and lift out the burner base. (The gas line
fl
ex-
connector should provide suf
fi
cient movement
to permit shifting the burner assembly to the
side).
F.
Reverse procedure to re-assemble.
SPACERS
SPACERS
S
!
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS
COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL
VOID THE WARRANTY AND CERTIFICATION.
ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE
APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER
CORD BENEATH THE APPLIANCE.
THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS. WHEN
INSTALLED, ENSURE THAT ANY EXCESS WIRE IS CONTAINED, PREVENTING IT FROM MAKING
CONTACT WITH MOVING OR HOT OBJECTS.
51.5