8
W415-1678 / B / 03.27.17
EN
2.4 RATING PLATE INFORMATION
W385-1987
Page 1 of 2
FOYER À GAZ VENTILÉ DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER,
UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS
MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE
SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280.
DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER A LA NORME
RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS
DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
POUR
UNE UTILISER AVEC BARRIÈRE W565-0144. SUIVEZ LES INSTRUCTIONS
D'INSTALLATION SE TROUVENT DANS LE MANUEL D'INSTALLATION
DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM, BATHROOM AND BED-SITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE
WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES,
IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND
SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED
HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
FOR USE WITH BARRIER
W565-0144. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.
9700539 (WSL)
4001657 (NGZ)
4001658 (NAC) 4001659
(WUSA)
0-4500FT (0-1370m)
ALTITUDE / ELEVATION
0-4500FT (0-1370m)
18,000 BTU/h
INPUT / ALIMENTATION
18,000 BTU/h
13,000 BTU/h REDUCED INPUT / ALIMENTATION REDUITE 13,500 BTU/h
MANIFOLD PRESSURE:
3.5" (9MB) WATER COLUMN
MANIFOLD PRESSURE:
10" (25MB) WATER COLUMN
PRESSION AU COLLECTEUR:
3.5" (9 MB) D'UNE COLONNE D'EAU
PRESSION AU COLLECTEUR:
10" (25MB) D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE:
4.5" (11MB) WATER COLUMN
MINIMUM SUPPLY PRESSURE:
11" (27MB) WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE:
4.5" (11MB) D'UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MINIMALE:
11" (27MB) D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE:
7.0" (17MB) WATER COLUMN
MAXIMUM SUPPLY PRESSURE:
13" (32MB) WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE:
7.0" (17MB) D'UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MAXIMALE:
13" (32MB) D'UNE COLONNE D'EAU
P4:
51.7%
P4:
51.7%
NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS DOORS
CERTIFIED WITH THIS UNIT ONLY.
WARNING:
THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE. REPLACE
ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES,
OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE. MINIMUM CLEARANCE
TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
TOP/ DESSUS
0
RECESSED DEPTH / PROFONDEUR D'ENCASTRE
16"
FLOOR / PLANCHER
0
VENT SIDES / COTES DE L'EVENT
1"
SIDES / COTES
0
VENT TOP / EVENT SUPERIEUR
3"
BACK / ARRIERE
0
VENT BOTTOM / EVENT INFERIEUR
1"
MANTEL / MANTEAU
2" *
* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE INSTRUCTION
MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL D'INSTRUCTION POUR DES
EXTENSIONS PLUS GRANDES.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR LES LONGUEURS
D'EVACUATION MINIMALE ET MAXIMALE.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET
APPAREIL. UTILISER AVEC LES PORTES VITREES HOMOLOGUEES
SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT:
CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION RAPIDE.
REMPLACEZ UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL LTÉE.
N’AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE OWNERS
INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS
NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST
IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRES AVOIR ASSURE LE MAINTIEN DU
SYSTEME DE PRISE D'AIR.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPPAREIL DE CHAUFFAGE.
ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: EP35
SERIAL NUMBER/NO. DE SERIE:
B36
MATERIAL:
10MIL LEXAN
MIN. LETTERING FOR "
NOT FOR USE WITH SOLID FUEL.
", "
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CELUI.
" TO BE 10 POINT ARIAL, BOLD FACE,
UPPER CASE AND 2 POINT LEADING SPACING OR EQUIVALENT. HOLE TO BE 0.250”
Ø
.
BLACK ON WHITE BACKGROUND
MAX OVERALL DECAL SIZE: 4.75" x 8.50"
HOLE IS 0.250”
Ø
/ 0.312 “FROM BOTTOM AND LEFT EDGE”
SERIAL NUMBERS TO BE ASCENDING FROM
B36231140
TITLE:
RATING PLATE B36(N)TR(E) / B36(P)TR(E)
REVISION:
DWG#:
W385-1987
DATE:
09.02.14_
JFK
B36NTR CB36NTR MODEL CB36PTR B36PTR
B36NTRE CB36NTRE CB36PTRE B36PTRE
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
A barrier designed to reduce the risk of burns from the hot viewing glass, is provided with the
appliance and must be installed.
SAMPLE