GX36-1 MINIMUM REAR VENT CLEARANCES
REAR EXIT ENCLOSURE
The appliance requires a minimum enclosure height of 44" (1.11m). For temperature requirements, the
enclosure space around and above the appliance must be left unobstructed.
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76.2mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
44
"
[1.11m]
10"-20"
[254mm-50.8cm]
VENT RUN
14 1/2"
[36.8cm]
1"-10"
[25mm-254mm]
VENT RUN
34 5/8"
[87.9cm]
9 3/8"
[238mm]
3"
[76.2mm]
44
"
[1.11m]
9 3/8"
[238mm]
NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible
wall penetration.
For rear vent termination not exceeding 10" (254mm) of horizontal vent run.