10 ALARM MESSAGES AND SOLUTIONS:
Cleaning alarm:
When the message "compulsory cleaning" appears on the display, the user need to start an automatic
cleanning on each groups (one after the other).
If it does only partially (1 group instead of 2, for example) or if it does not, the machine will no longer be used
and the message "Warning cleaning groups" remain permanently displayed on the display.
This message will disappear when all groups have been cleaned.
The machine comes back to NORMAL MODE.
Cleanning Gr : X SVP
After 250 coffees on one group, the display shows «Please Cleaning Gr: X»
The machine is usable, but the message will not disappear until the cleaning has not been made. To remove the
alarm, simply run an automatic cleaning (see chapter: use)
Nota:
Automatic cleaning is always possible even if there is no message on the display.
Filling up time out:
The high level probe SN did not detect water within the programmed time (250 sec).
Possible reasons:
Water inlet solenoid valve must be cleaned.
Water inlet solenoid valve does not work.
Water high level probe is disconnected.
Water inlet tap is closed.
Solution:
After checking up, cut the mains then put it back.
Boiler temperature alarm message
The electronics detected a temperature > 140 °C for more than 5 seconds in the boiler.
Alarm message disappears when temperature decreases 2°C under the limit.
Temperature probe open
The electronics does not detect the temperature probe.
Possible reasons:
Reconnect or replace the temperature probe.
Check temperature probe cable, replace if necessary
Mother board may be damaged
Check the connector on the mother board
Flowmeter alarm Gr X
The electronics does not receive group X flowmeter information.
Possible reasons:
No water in the flowmeter
Damaged cables
Damaged flowmeter
Coffee too fine
The water inlet tap is closed.
Water softener maintance alarm: