D-6
Appendix D --- Error codes
System Error:
100-3009
Description:
Unable to adjust camera B down (CIS 3 or 4)
Corrective Action.
Try the following:
■
Please clean the white background / Pressure rollers and the glass plate.
■
Then calibrate the scanner.
System Error:
100-3010
Description:
Unable to adjust camera C down (CIS 5 or 6)
Corrective Action.
Try the following:
■
Please clean the white background / Pressure rollers and the glass plate.
■
Then calibrate the scanner.
System Error:
100-3014
Description:
Unable to stitch cameras A and B (CIS 1, 2, 3 or 4)
Corrective Action.
Try the following:
■
Please clean the white background / Pressure rollers and the glass plate.
■
Then calibrate the scanner.
System Error:
100-3015
Description:
Unable to stitch cameras B and C (CIS 3, 4, 5 or 6)
Corrective Action.
Try the following:
■
Please clean the white background / Pressure rollers and the glass plate.
■
Then calibrate the scanner.
System Error:
100-3019
Description:
Error calibrating
Corrective Action.
Try the following:
■
Please clean the white background / Pressure rollers and the glass plate.
■
Then calibrate the scanner.
System Error:
100-3051
Description:
The scanner’s ID switch has been set to an invalid value.
Corrective Action.
Try the following:
■
Please correct ID switch setting on Scanner control Board, SUL.
■
Check that all the cables are connected correctly to the Scanner control Board, SUL
■
Run SCANtest, test 1. See Appendix A
■
Check dip switches on Scanner Control Board, SUL
■
Replace the Scanner control Board, SUL
System Error:
100-3061
Description:
There is a problem with the Interface Board
Corrective Action.
.
Try the following:
■
Check that the Interface Board is correctly installed.
■
Re-power on scanner
■
Replace the Interface Board IMx