4-7
Part replacement MG52D
1. Lift up connector lock.
2. Pull out USB connector and cable.
Replace USB cable and reverse steps.
Remove RHS cover, see page 4-5
Stepper Motor Assy.
*Switch Scanner off and disconnect from power source and PC prior to any repair.
1. Loosen screw.
2. Release tension on belt by lifting upward
and tighten nut again.
3. Disconnect cable.
4. Remove screws and motor.
1. Remove screws.
2. Remove motor mount.
Install the new Motor and reverse the steps.
Adjust Belt tension, see page 4-8.