Contemporary Research ICE-HE-DXL Product Manual Download Page 7

Page | 7 

 

ICE-HE-DXL Display Control Center Product Manual 042021 

 

Setup Notes 

 

Interfacing with a Control System 

The unit may receive iCC-Net command strings from a Display Express server PC or a third-party control processor.  The command strings  
may be received at the following interfaces. 

 

TCP at port 2728 

 

RS-232 via the DB-9 port 

 

RS-232 via either USB virtual com port 

 
Only one TCP socket is supported.  The buffered data bus allows for commands to be received concurrently from any of the interfaces.  
 

Display Express Lite

 

The ICE-HE-DXL includes an embedded web server that hosts the Display Express Lite web page.  Display Express Lite supports basic control 
of power, volume, and channel selection for any combination of up to 128 display controllers, tuner/controllers, or IPTV 
decoder/controllers.  The web page may be accessed from the web browser of a connected device either wired or through a Wi-Fi access 
point. 
 

IP Network Settings 

The IP Address, Default Gateway, and Subnet Mask may be set in the front panel Network menu or via RS-232 command.  The current IP 
address may be displayed on the front panel by holding the Setup button.  The default IP address is 192.168.1.251.  Changes to any of 
network settings require a power cycle or reboot. 
 

RS-232 

The DB-9 RS-232 port may be used for control, configuration, and firmware updates.  The baud rate settings apply to the DB-9 RS-232 port 
and the rear panel USB virtual com port.  Baud Rate settings are available in the front panel System menu or may be changed via RS-232 or 
telnet serial command.  The default baud rate is 19,200.  Changes to the baud rate setting is instantaneous and no power cycle or reboot is 
required. 
 

USB Virtual Com Ports 

The front and rear panel USB virtual com ports may be used for control, configuration, and firmware updates.  Windows 10 will 
automatically load the appropriate driver.  The baud rate setting applies to the rear panel USB port.  The baud rate for the front panel USB 
port is fixed at 115.2K.

 

 

UDP Control 

The iCC-Net commands that are transmitted via the RF output may be duplicated and transmitted as UDP directed broadcast data packets 
for control of QIP-D and QIP-DVX IPTV decoder/controllers and 232-ATSC 4i and ATSC-SDI 4i HDTV tuners.  This function may be enabled or 
disabled in the front panel menu or via RS-232 command.  It is enabled by default.

 

 

I/O Port 

Inputs may accept a 0-24 VDC control voltage or contact closure to ground.  A closed contact closure creates a logical low, an open contact 
closure creates a logical high. 
 
Outputs are open collector and may require a pull-up resistor; 28 VDC max, 200 mA max. A logic level high turns on the transistor and 
creates a current path to ground. 
 

Simplified Output Circuit 

 

Typical Application 

 

 

 

 
 
 
 
 
 

Summary of Contents for ICE-HE-DXL

Page 1: ...Product Manual 972 931 2728 888 972 2728 www contemporaryresearch com...

Page 2: ...mands 8 iCC Net Control Overview 10 Building an RF Based Control System 10 Compatible RF Control System Components 11 RF System Control Data Flow Examples 12 Building an RF IPTV Hybrid Control System...

Page 3: ...are is easy to configure and may be used for control of up to 128 display controllers or tuner controllers Control functions include power on off volume and channel selection from up to 32 source chan...

Page 4: ...onfiguration menu category Press SELECT to enter the menu Press the Up Down arrows to view the settings Press the Left Right arrows to step through the setting options Press SELECT to save the changes...

Page 5: ...Board Rev C1 Hardware version Network IP Address 192 168 1 251 IP Mode Static DHCP Gateway 000 000 000 000 Subnet Mask 255 255 255 000 MAC SN 0 14 C8 10 xx xx UDP Reply On Off UDP Control On Off Comma...

Page 6: ...configurations and firmware updates I O Logic control port 6 pin captive screw terminal 1 PWR Power 12 VDC 250 mA max using the included 500 mA power supply 2 OUT2 Output 2 3 OUT1 Output 1 4 IN2 Input...

Page 7: ...232 port may be used for control configuration and firmware updates The baud rate settings apply to the DB 9 RS 232 port and the rear panel USB virtual com port Baud Rate settings are available in the...

Page 8: ...HE DXL begin with the ASCII greater than symbol as an Attention character and end with carriage return ASCII CR Hex 0D or keyboard Enter as an End of command character Responses from the ICE HE DXL b...

Page 9: ...2 168 001 001 IM 255 255 255 000 IY 1 S or D at end of IP indicates DHCP or Static address 000 000 000 000 indicates DHCP but no DHCP server detected IY IP Address Mode 1 Static 2 DHCP MC MAC Address...

Page 10: ...4 and 5 The RF output of the ICE HE DXL is combined with the CATV channels at the head end prior to distribution When connected to an IPTV network the ICE HE DXL will simultaneously send the same iCC...

Page 11: ...splays may be controlled as individual units as defined groups or as all Supports up to 32 source channels Third Party Control System A third party control system may be used as the control system int...

Page 12: ...mory RS 232 display type selectable using on screen communication menu command from the ICE HE DXL front panel iCC Net command to the ICE HE DXL or RS 232 command via the serial port HDMI CEC configur...

Page 13: ...display specific commands for display control The display controllers have an RF pass through for connection to the display s integrated tuner The tuner controller replaces the function of a display...

Page 14: ...ontroller The QIP DVX is a combination IPTV decoder controller The unit is a full functioned MPEG TS IPTV decoder equipped with a display controller Receives ICC Net IP commands RS 232 port IR output...

Page 15: ...Center Product Manual 042021 RF IPTV Hybrid System Control Data Flow Examples iCC Net Control Data Flow with RF IPTV Hybrid System Using Display Express iCC Net Control Data Flow with RF IPTV Hybrid...

Page 16: ...Page 16 ICE HE DXL Display Control Center Product Manual 042021 iCC Net Control Data Flow with RF System Using Third Party Control...

Page 17: ...e numbers 257 to 384 The display device number is represented in the iCC Net command string by the zone number and the unit number The hex equivalent of the zone number and the unit number is equal to...

Page 18: ...they are not part of the protocol Double quotes enclose the command string but they are not part of the protocol A Decimal ASCII Hex conversion chart may be found at www asciitable com String Format E...

Page 19: ...55 H1 Tuning Style 0 No Change in tuning style 1 Five digit one part channel Major high byte Minor low byte Formula high byte x 256 low byte channel number 2 Two part virtual channel number Major Mino...

Page 20: ...t an action The action can be a channel selection volume or power command Selecting the Clear button will clear the selected Groups or TVs Display Express Lite by default will send the iCC Net control...

Page 21: ...ht corner Select Toggle Edit Mode from the pop up menu TVs TVs may be added deleted and assigned to Groups Each TV button may be renamed The Label field supports up to ten characters Each TV button wi...

Page 22: ...amed The Label field supports up to ten characters To add a channel select an existing channel modify it with the new channel settings and click Add The new channel will be added in the same column as...

Page 23: ...wo components in one RU rack space use the two short rack ears and the tie bar assembly Note that older versions of the QDA4 45 and QCA9 33 have solid side panels and should not be mounted next to act...

Page 24: ...ontrol system 1200 to 115 2K baud 19 2K default 8 data bits no parity 1 stop bit USB Control Mini USB B virtual com port for control configuration and firmware updates I O Logic control port 6 pin cap...

Page 25: ...to this product through openings as they may touch dangerous voltage points or short out parts resulting in a fire or electric shock Never spill liquid of any kind on the product Servicing Do not atte...

Page 26: ...Contemporary Research dealers Include the assigned RMA number in all correspondence with Contemporary Research Write the assigned RMA number clearly on the shipping label of the box when returning th...