Page | 24
ICE-HE-DXL Display Control Center Product Manual 042021
Specifications
Physical
Size (HWD):
8.5” [216
mm] wide x 1.73
” [44
mm] high (1
RU) x 8.0” [203mm] deep
Weight:
1.88 lbs [854 g]
Enclosure:
Aluminum with black powder coat paint
Mounting:
1 RU Rack mounting for one- or two-units side-by-side (RKU, RK1, RK2EZ)
Cooling:
Active cooling not required for normal applications.
Front Panel
Display:
Text display, white text on blue LCD
Control:
Setup, Select, and Up/Down/Left Right navigation buttons
USB:
Mini USB-B virtual com port for control, configuration, and firmware updates
Rear Panel
Ethernet:
RJ-45 10/100 Ethernet connector for Web page access, Telnet, UDP control, and IPTV Streaming
RS-232
: DB-9 male, RS-232 data link to control system, 1200 to 115.2K baud (19.2K default), 8 data bits, no parity, 1 stop bit
USB Control
: Mini USB-B virtual com port for control, configuration, and firmware updates
I/O:
Logic control port 6-pin captive screw terminal
1
–
PWR+
Power, 12 VDC, 250 mA max (using the included 500 mA power supply)
2
–
OUT2
Output 2
3
–
OUT1
Output 1
4
–
IN2
Input 2
5
–
IN1
Input 1
6
–
GND-
Ground
Power In
: 2.1mm coaxial jack (inside center conductor positive), 1.1 A maximum, 11 to 18 VDC, 12 VDC typical, 250 mA maximum, 45 BTU
RF In:
‘F’ female 75 ohm impedance for future use
RF Out:
‘F’ female, 75 ohm impedance, RF to CATV distribution
system
Data Transmit: Mid-band VHF, 74.7 MHz, +14 to +45 dBmV, adjustable from front panel
±80 KHz max carrier deviation
Includes
PS12-500 Power Supply, 500 mA maximum, 12 VDC (5400-001)
RKU Universal Rack Kit
Options
RK1 Single Rack Kit, 1RU (5008-001)
RK2EZ Dual Rack Kit, 1RU (5008-015)
CC-COM-B RS-232 Null Modem Cable (5061-003)