Page | 20
ICC1-TC Tuner/Controller Product Manual 082020
Table of iCC-Net Control Commands
Code
Function
Operation
Power
P1
Power On
"$A5,<dh>,<dl>,2,'P1'" (6 bytes)
P0
Power Off
"$A5,<dh>,<dl>,2,'P0'" (6 bytes)
PT
Power Toggle
"$A5,<dh>,<dl>,2,'PT'" (6 bytes)
LM
Control Lock
"$A5,<dh>,<dl>,3,'LM',<Control>" (7 bytes)
Locks out ICC1-TC control from an IR remote or front-panel buttons.
<Control> Total value of control options below
0=Disabled
1=Front panel button lockout enabled
64=Volume control lockout enabled
128=IR remote sensor disabled
Example:
"$A5,6,124,3,'LM',193" Device 1660, Locks out all control
Channel Selection
TH
Set Digital Channel
"$A5,<dh>,<dl>,5,'TH',<H1>,<Major>,<Minor>" (9 bytes)
Sets digital channel with one-part virtual channel numbers and two-part channel numbers up to 255-
255
<H1> Tuning Style
0=No Change in tuning style
1=Five digit one-part channel (Major=high byte, Minor=low byte)
Formula: (high byte x 256) + low byte = channel number
2=Two-part virtual channel number (Major-Minor)
3=Two-part physical channel number (Major-Minor)
Examples:
"$A5,1,4,5,'TH',2,2,3" Device 260, virtual channel 2-3
"$A5,1,4,5,'TH',1,1,69" Device 260, channel 325 (256+69)
TJ
Set Digital Channel
"$A5,<dh>,<dl>,6,'TJ',<Major high>,<Major low>,<Minor high>,<Minor low>" (10 bytes)
Sets digital channel with two-part virtual channel numbers up to 999-999
Formula: (high byte x 256) + low byte = channel number
Example:
"$A5,2,44,6,'TJ',1,40,0,1" Device 580, channel 296-1
TC
Set Analog Channel
"$A5,<dh>,<dl>,3,'TC',<Channel>" (7 bytes)
H1
Tuning Style
"$A5,<dh>,<dl>,3,'H1',<Style>" (7 bytes)
Sets the tuning style used with the TH channel command. This setting is stored in memory and only
needs to be sent one time. Subsequent TH channel commands may have the <H1> byte set to 0.
<Style>
1=Five digit one-part virtual channel number
2=Two-part major-minor virtual channel number
3=Two-part major-minor physical channel number